Evidence map›Paper›PMID 33917742›Full record

ArticleSensors (Basel, Switzerland)2021

Simulation Study of a Frame-Based Motion Correction Algorithm for Positron Emission Imaging.

Héctor Espinós-Morató, David Cascales-Picó, Marina Vergara, Ángel Hernández-Martínez, José María Benlloch Baviera, María José Rodríguez-Álvarez

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Computer Vision for 3D Perception and Applications.Sensors (Basel, Switzerland) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Héctor Espinós-MoratóInstituto de Instrumentación para Imagen Molecular (i3M), Centro Mixto CSIC-Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0002-4089-1368
David Cascales-PicóInstituto de Instrumentación para Imagen Molecular (i3M), Centro Mixto CSIC-Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0003-1743-1678
Marina VergaraInstituto de Instrumentación para Imagen Molecular (i3M), Centro Mixto CSIC-Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0002-3625-5588
Ángel Hernández-MartínezInstituto de Instrumentación para Imagen Molecular (i3M), Centro Mixto CSIC-Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0003-2117-757X
José María Benlloch BavieraInstituto de Instrumentación para Imagen Molecular (i3M), Centro Mixto CSIC-Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0001-6073-1436
María José Rodríguez-ÁlvarezInstituto de Instrumentación para Imagen Molecular (i3M), Centro Mixto CSIC-Universitat Politècnica de València, 46022 Valencia, Spain.ORCID 0000-0001-8333-8792
Instituto de Instrumentación para Imagen Molecular · ES

Funding

European Union through the European Regional Development Fund (ERDF) and by the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program Grant Agreement No. 695536Spanish Government Grant PEJ2018-002230-A-ARSpanish Government Grant PID2019-107790RB-C22Spanish Government Grant PTA2019-017113-1/AEI/10.13039/501100011033Spanish Government Grant TEC2016-79884-C
6 · The paper itself

Abstract

Positron emission tomography (PET) is a functional non-invasive imaging modality that uses radioactive substances (radiotracers) to measure changes in metabolic processes. Advances in scanner technology and data acquisition in the last decade have led to the development of more sophisticated PET devices with good spatial resolution (1-3 mm of full width at half maximum (FWHM)). However, there are involuntary motions produced by the patient inside the scanner that lead to image degradation and potentially to a misdiagnosis. The adverse effect of the motion in the reconstructed image increases as the spatial resolution of the current scanners continues improving. In order to correct this effect, motion correction techniques are becoming increasingly popular and further studied. This work presents a simulation study of an image motion correction using a frame-based algorithm. The method is able to cut the acquired data from the scanner in frames, taking into account the size of the object of study. This approach allows working with low statistical information without losing image quality. The frames are later registered using spatio-temporal registration developed in a multi-level way. To validate these results, several performance tests are applied to a set of simulated moving phantoms. The results obtained show that the method minimizes the intra-frame motion, improves the signal intensity over the background in comparison with other literature methods, produces excellent values of similarity with the ground-truth (static) image and is able to find a limit in the patient-injected dose when some prior knowledge of the lesion is present.

Indexed as

ElectronsImage Processing, Computer-AssistedAlgorithmsHumansMotionMovementPhantoms, ImagingPositron-Emission Tomographymotion correctionmulti-framesimulation studyspatio-temporal registration

Identifiers

PMID33917742
PMCPMC8068167
OpenAlexW3147397294

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.