Evidence map›Paper›PMID 33916110›Full record

ArticleJournal of clinical medicine2021

Patient-Specific Instrumentation Accuracy Evaluated with 3D Virtual Models.

Vicente J León-Muñoz, Andrea Parrinello, Silvio Manca, Gianluca Galloni, Mirian López-López, Francisco Martínez-Martínez, Fernando Santonja-Medina

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Vicente J León-MuñozDepartment of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain.ORCID 0000-0002-0429-2579
Andrea ParrinelloProduct Management Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland.
Silvio MancaPatient Matched Technology Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland.
Gianluca GalloniPatient Matched Technology Department, Medacta International SA, Strada Regina, 6874 Castel San Pietro, Switzerland.
Mirian López-LópezSubdirección General de Tecnologías de la Información, Servicio Murciano de Salud, Avenida Central, 7, Edificio Habitamia, Espinardo, 30100 Murcia, Spain.
Francisco Martínez-MartínezDepartment of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain.
Fernando Santonja-MedinaDepartment of Orthopaedic Surgery and Traumatology, Hospital Clínico Universitario Virgen de la Arrixaca, Ctra. Madrid-Cartagena, s/n, 30120 Murcia, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

There have been remarkable advances in knee replacement surgery over the last few decades. One of the concerns continues to be the accuracy in achieving the desired alignment. Patient-specific instrumentation (PSI) was developed to increase component placement accuracy, but the available evidence is not conclusive. Our study aimed to determine a PSI system's three-dimensional accuracy on 3D virtual models obtained by post-operative computed tomography. We compared the angular placement values of 35 total knee arthroplasties (TKAs) operated within a year obtained with the planned ones, and we analyzed the possible relationships between alignment and patient-reported outcomes. The mean (SD) discrepancies measured by two experienced engineers to the planned values observed were 1.64° (1.3°) for the hip-knee-ankle angle, 1.45° (1.06°) for the supplementary angle of the femoral lateral distal angle, 1.44° (0.97°) for the proximal medial tibial angle, 2.28° (1.78°) for tibial slope, 0.64° (1.09°) for femoral sagittal flexion, and 1.42° (1.06°) for femoral rotation. Neither variables related to post-operative alignment nor the proportion of change between pre-and post-operative alignment influenced the patient-reported outcomes. The evaluated PSI system's three-dimensional alignment analysis showed a statistically significant difference between the angular values planned and those obtained. However, we did not find a relevant effect size, and this slight discrepancy did not impact the clinical outcome.

Indexed as

alignmentkneepatient matched technologythree-dimensional analysistotal knee arthroplastytotal knee replacement

Identifiers

PMID33916110
PMCPMC8036812

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.