Evidence map›Paper›PMID 33916047›Full record

ArticleCancers2021

Clinical Implications of Geometric and Dosimetric Uncertainties of Inter- and Intra-Fractional Movement during Volumetric Modulated Arc Therapy for Breast Cancer Patients.

Jason Joon Bock Lee, Ik Jae Lee, Yeonho Choi, Mi Jin Jeon, Il Hun Jung, Ho Lee

Open access · goldAbstract read
In one paragraph

Article in Cancers, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jason Joon Bock LeeDepartment of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Korea.ORCID 0000-0003-3170-1427
Ik Jae LeeDepartment of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Korea.
Yeonho ChoiDepartment of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Korea.
Mi Jin JeonDepartment of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Korea.
Il Hun JungDepartment of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Korea.
Ho LeeDepartment of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06273, Korea.ORCID 0000-0001-5773-6893
Yonsei University · KR

Funding

Korea Health Industry Development Institute HI19C1330National Research Foundation of Korea 2019R1I1A1A01062157Yonsei University College of Medicine 6-2019-0080
6 · The paper itself

Abstract

With the introduction of modern sophisticated radiotherapy (RT) techniques, the significance of accuracy has increased considerably. This study evaluated the necessity of pre-treatment and intra-fractional cone-beam computed tomography (CBCT) by analyzing inter- and intra-fractional CBCT images of breast cancer patients receiving RT. From 57 patients, 1206 pre-treatment CBCT and 1067 intra-fractional CBCT images were collected. Geometric movements of patients were measured quantitively in both inter- and intra-fractional CBCT, and changes in dosimetric parameters were evaluated in selected patients with extreme intra-fractional movement. For right-sided breast cancer patients, left-sided breast cancer patients treated using deep-inspiration breath hold (DIBH), and left-sided breast cancer patients treated using continuous positive airway pressure (CPAP), median inter-fractional deviations were 0.53 (range 0.06-2.98) cm, 0.66 (range 0.08-4.41) cm, and 0.69 (range 0.04-3.80) cm, and median intra-fractional deviations were 0.14 (range 0.00-0.62) cm, 0.23 (range 0.02-0.96) cm, and 0.24 (0.00-1.15) cm, respectively. Modified plans reflecting large changes in intra-fractional position in 10 selected cases revealed insufficient target coverage in seven cases and more than 20-fold increase in the volume of heart receiving at least 25 Gy in two cases. Intra-fractional verification, as well as pre-treatment verification, might be considered in patients using DIBH or CPAP.

Indexed as

breast cancercone-beam computed tomographyimage-guided radiotherapyintrafraction motionvolumetric modulated arc therapy

Identifiers

PMID33916047
PMCPMC8036414
OpenAlexW3148393153

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.