Evidence map›Paper›PMID 33913872›Full record

ArticleIndian journal of ophthalmology2021

A novel approach to anterior segment imaging with smartphones in the COVID-19 era.

Sreetama Dutt, Siva S Vadivel, Shanmuganathan Nagarajan, Amrutha Galagali, Josephine S Christy, Anand Sivaraman, Divya Parthasarathy Rao

Open access · diamondAbstract read
In one paragraph

Article in Indian journal of ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Sreetama DuttResearch & Development, Remidio Innovative Solutions Pvt. Ltd., Bengaluru, Karnataka, India.
Siva S VadivelResearch & Development, Remidio Innovative Solutions Pvt. Ltd., Bengaluru, Karnataka, India.
Shanmuganathan NagarajanResearch & Development, Remidio Innovative Solutions Pvt. Ltd., Bengaluru, Karnataka, India.
Amrutha GalagaliResearch & Development, Remidio Innovative Solutions Pvt. Ltd., Bengaluru, Karnataka, India.
Josephine S ChristyCornea & Refractive Services, Aravind Eye Hospital, Pondicherry, India.
Anand SivaramanResearch & Development, Remidio Innovative Solutions Pvt. Ltd., Bengaluru, Karnataka, India.
Divya Parthasarathy RaoResearch & Development, Remidio Innovative Solutions Pvt. Ltd., Bengaluru, Karnataka, India.
Aravind Eye Hospital · INRemidio Innovative Solutions (India) · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo report a novel, telemedicine-friendly, smartphone-based, wireless anterior segment device with instant photo-documentation ability in the COVID-19 era.

methodsAnterior Imaging Module (AIM) was constructed based on a 50/50 beam splitter design, to match the magnification drum optics of slit-lamps with a three-step or higher level of magnification. The design fills the smartphone sensor fully at the lowest magnification and matches the fixed focus of the slit-lamp. It comes with a smartphone for instant photo-documentation, an in-built software application for data-management and secure HIPAA compliant cloud storage, and a Bluetooth trigger for a one-tap image capture. The construction of the device is explained, and the optical resolution measured using U.S. air-force resolution test. AIM's performance was characterized with traceability to internationally relevant performance standards for digital slit-lamps after image quality assessment through a pilot study.

resultsClinically useful anterior segment images were obtained with both diffuse and slit illumination at different magnification settings with the highest magnification (40X) resolution of 359 lines per cm and the lowest magnification (16X) resolution of 113 lines per cm.

conclusionAIM is a novel, wireless, telemedicine-enabled design that digitizes existing, analog slit lamps with at least three-step magnification. The settings ensure the focus is determined purely by the position of the slit-lamp. Hence, the image viewed and captured on the smartphone is exactly what the clinician sees through the eyepiece. This helps in maintaining distance from the patient in the ongoing COVID-19 pandemic, as well.

Indexed as

COVID-19SmartphoneHumansPandemicsPilot ProjectsSARS-CoV-2Anterior segment imagingconjunctivacorneaCOVID-19irislensscleraslit-lampsmartphonetelemedicineuniform illumination

Identifiers

PMID33913872
PMCPMC8186572
OpenAlexW3157709898

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.