ArticleScientific reports2021
Flow-diverting devices in the treatment of unruptured ophthalmic segment aneurysms at a mean clinical follow-up of 5 years.
Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Flow diversion for compressive unruptured internal carotid artery aneurysms with neuro-ophthalmological symptoms: a systematic review and meta-analysis.Journal of neurointerventional surgery · 2023Pooled it
- Mid- and Long-Term Outcomes Following Flow Diversion for Carotid-Ophthalmic Aneurysms: a Single-Centre Experience.Clinical neuroradiology · 2026Article
- Article
- Endovascular treatment for a symptomatic dissecting ophthalmic artery aneurysm occurring in the orbit: illustrative case.Journal of neurosurgery. Case lessons · 2025Article
- Conventional endovascular treatment and flow diverter for unruptured small- and medium-sized paraophthalmic segment aneurysms.Frontiers in neurology · 2025Article
- Stent-assisted coiling of unruptured paraclinoid aneurysms with wide neck or unfavorable dome-to-neck ratio: Results of ventral wall vs dorsal wall with propensity score matching analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Article
- Systematic Review and Meta-Analysis of Endovascular Therapy Effectiveness for Unruptured Saccular Intracranial Aneurysms.Stroke (Hoboken, N.J.) · 2024Article
- The EP-VRD2 for endovascular treatment of ophthalmic segment aneurysms: wall apposition and long-term study.Frontiers in neurologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A shift toward the endovascular treatment of ophthalmic segment aneurysms is noticeable. However, it is not clear if the long-term treatment results improve with the development of endovascular methods. The aim of this study was to present the outcomes of the treatment of unruptured ophthalmic aneurysms using flow diverting devices (FDD) with or without coiling. This retrospective study included 52 patients with 65 UIAs treated in 2009-2016. The mean aneurysm size was 8.8 mm. Eight aneurysms were symptomatic. Therapeutic procedures included: 5 failed attempts, 55 first sessions with FDD deployment (bilateral procedures in 3) and 3 retreatment procedures. To cover 55 ICAs, 25 Silk, 26 Pipeline, 9 Fred and 1 Surpass FDD were used. FDD with coiling was applied in 19(29.2%), mainly for symptomatic and larger aneurysms. Mean radiological and clinical follow-up was 12 and 61 months, respectively. Postprocedural deterioration was noted in 3(5.8%) patients, but in long-term the modified Rankin Scale grades 0-2 were achieved in 98.1% of patients. One patient died from the treated aneurysm rupture (annual risk-0.07%). Raymond-Roy occlusion classification class I or II was achieved in 98.5% in the long term, with similar results in both groups. Complications occurred in 40.4% of patients and the most frequent were: imperfect FDD deployment (15%), failed attempt of FDD deployment (9.6%) and late FDD stenosis (9.6%). Flow-diverting devices, with additional coiling in selected cases, may offer a very high proportion of satisfactory outcomes. However, in our experience the high risk of complications remains.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.