Evidence map›Paper›PMID 33909252›Full record

ArticleMedical & biological engineering & computing2021

Space-time filter for SSVEP brain-computer interface based on the minimum variance distortionless response.

Sarah Negreiros de Carvalho, Guilherme Vettorazzi Vargas, Thiago Bulhões da Silva Costa, Harlei Miguel de Arruda Leite, Luís Coradine, Levy Boccato, Diogo Coutinho Soriano, Romis Attux

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Sarah Negreiros de CarvalhoInstitute of Exact and Applied Sciences, Federal University of Ouro Preto, UFOP, Ouro Preto, Brazil. sarah@ufop.edu.br.ORCID http://orcid.org/0000-0003-2316-7244
Guilherme Vettorazzi VargasSchool of Computer and Electrical Engineering, University of Campinas, UNICAMP, Campinas, Brazil.
Thiago Bulhões da Silva CostaBrazilian Institute of Neuroscience and Neurotechnology, BRAINN, Campinas, Brazil.
Harlei Miguel de Arruda LeiteInstitute of Exact and Applied Sciences, Federal University of Ouro Preto, UFOP, Ouro Preto, Brazil.
Luís CoradineInstitute of Computing, Federal University of Alagoas, UFAL, Maceió, Brazil.
Levy BoccatoSchool of Computer and Electrical Engineering, University of Campinas, UNICAMP, Campinas, Brazil.
Diogo Coutinho SorianoBrazilian Institute of Neuroscience and Neurotechnology, BRAINN, Campinas, Brazil.
Romis AttuxBrazilian Institute of Neuroscience and Neurotechnology, BRAINN, Campinas, Brazil.
Universidade Estadual de Campinas (UNICAMP) · BRUniversidade Federal de Ouro Preto · BRBrazilian Institute of Neuroscience and Neurotechnology · BRUniversidade Federal de Alagoas · BR

Funding

CAPES 001CNPq 305616/2016-1CNPq 308811/2019-4FAPESP 2013/07559-3FAPESP 2019/09512-0FINEP 01.16.0067.00
6 · The paper itself

Abstract

Brain-computer interfaces (BCI) based on steady-state visually evoked potentials (SSVEP) have been increasingly used in different applications, ranging from entertainment to rehabilitation. Filtering techniques are crucial to detect the SSVEP response since they can increase the accuracy of the system. Here, we present an analysis of a space-time filter based on the Minimum Variance Distortionless Response (MVDR). We have compared the performance of a BCI-SSVEP using the MVDR filter to other classical approaches: Common Average Reference (CAR) and Canonical Correlation Analysis (CCA). Moreover, we combined the CAR and MVDR techniques, totalling four filtering scenarios. Feature extraction was performed using Welch periodogram, Fast Fourier transform, and CCA (as extractor) with one and two harmonics. Feature selection was performed by forward wrappers, and a linear classifier was employed for discrimination. The main analyses were carried out over a database of ten volunteers, considering two cases: four and six visual stimuli. The results show that the BCI-SSVEP using the MVDR filter achieves the best performance among the analysed scenarios. Interestingly, the system's accuracy using the MVDR filter is practically constant even when the number of visual stimuli was increased, whereas degradation was observed for the other techniques.

Indexed as

Brain-Computer InterfacesAlgorithmsElectroencephalographyEvoked PotentialsEvoked Potentials, VisualHumansPhotic StimulationBrain-computer interfaceMinimum variance distortionless responseSpatial filteringSteady-state visually evoked potentialTemporal filtering

Identifiers

PMID33909252
OpenAlexW3159674604

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.