Evidence map›Paper›PMID 33908215›Full record

ArticleYonsei medical journal2021

Accuracy of 2D CT-Based Measurements of Rotational Alignment of the Femoral Component for Total Knee Arthroplasty.

Jun Young Park, Hyuck Min Kwon, Byung Woo Cho, Woo Suk Lee, Ick Hwan Yang, Kwan Kyu Park

Open access · goldAbstract read
In one paragraph

Article in Yonsei medical journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Jun Young ParkDepartment of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-4713-4036
Hyuck Min KwonDepartment of Orthopedic Surgery, Yong-In Severance Hospital, Yonsei University College of Medicine, Yongin, Korea.ORCID https://orcid.org/0000-0002-2924-280X
Byung Woo ChoDepartment of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-7472-4103
Woo Suk LeeDepartment of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-0798-1660
Ick Hwan YangDepartment of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.ORCID https://orcid.org/0000-0002-6959-6207
Kwan Kyu ParkDepartment of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea. kkpark@yuhs.ac.ORCID https://orcid.org/0000-0003-0514-3257
Yonsei University · KRSeverance Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe aimed to investigate the accuracy of two-dimensional computed tomography (2D-CT)-based methods for measuring rotational alignment of the femoral component during total knee arthroplasty in comparison to reference values for three-dimensional (3D) reconstruction. MATERIALS AND

methodsWe selected the "most protruding transepicondylar axis section," "most protruding posterior condylar line section," and "distal femoral cut section" on 2D-CT images for 100 knees. We investigated posterior condylar angle (PCA) and condylar twist angle (CTA) values using three different methods on 2D-CT and compared to these values to those obtained using a 3D model.

resultsThe mean PCA and CTA values were 2.8° and 7.0° on the 3D model and 2.0° to 2.1° and 5.9° to 6.0° on 2D-CT, respectively. Errors in PCA and CTA measurement included internal rotation of 0.8° and 1.1° with the 1-plane and 2-plane methods and 0.9° and 1.0° with the assumed resection method, respectively.

conclusionMean errors in PCA and CTA values measured using three different methods on 2D-CT were not significantly different. However, PCA and CTA values measured on 2D-CT were approximately 1° smaller than their 3D values. Thus, we suggest that adding 1° to the mean PCA and CTA values obtained from a single plane of 2D-CT would provide values similar to those obtained from 3D reconstruction.

Indexed as

Arthroplasty, Replacement, KneeOsteoarthritis, KneeFemurHumansKnee JointReference ValuesRotationTomography, X-Ray Computed2D-CT3D reconstructionKneeosteoarthritisrotational alignment of the femoral componenttotal knee arthroplasty

Identifiers

PMID33908215
PMCPMC8084701
OpenAlexW3159733707

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.