Evidence map›Paper›PMID 33902515›Full record

ArticleBMC pulmonary medicine2021

Innovative method for Amplatzer device implantation in patients with bronchopleural fistulas.

Jisong Zhang, Huihui Hu, Li Xu, Shan Xu, Jihong Zhu, Fengjie Wu, Enguo Chen

Open access · goldAbstract read
In one paragraph

Article in BMC pulmonary medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Bronchoscopic interventions for bronchopleural fistulas.Therapeutic advances in respiratory disease
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jisong ZhangDepartment of Pulmonary and Critical Care Medicine, Sir Run Run Shaw Hospital of Zhejiang University, No. 3 East Qingchun Road, Jianggan District, Hangzhou, 310016, Zhejiang Province, China.
Huihui HuDepartment of Pulmonary and Critical Care Medicine, Sir Run Run Shaw Hospital of Zhejiang University, No. 3 East Qingchun Road, Jianggan District, Hangzhou, 310016, Zhejiang Province, China.
Li XuDepartment of Pulmonary and Critical Care Medicine, Sir Run Run Shaw Hospital of Zhejiang University, No. 3 East Qingchun Road, Jianggan District, Hangzhou, 310016, Zhejiang Province, China.
Shan XuDepartment of Pulmonary and Critical Care Medicine, Sir Run Run Shaw Hospital of Zhejiang University, No. 3 East Qingchun Road, Jianggan District, Hangzhou, 310016, Zhejiang Province, China.
Jihong ZhuDepartment of Anesthesiology, Sir Run Run Shaw Hospital of Zhejiang University, Hangzhou, Zhejiang Province, China.
Fengjie WuDepartment of Pulmonary and Critical Care Medicine, The Second Hospital of Jiaxing, Jiaxing, Zhejiang Province, China.
Enguo ChenDepartment of Pulmonary and Critical Care Medicine, Sir Run Run Shaw Hospital of Zhejiang University, No. 3 East Qingchun Road, Jianggan District, Hangzhou, 310016, Zhejiang Province, China. 3195024@zju.edu.cn.ORCID http://orcid.org/0000-0003-2338-8610
Sir Run Run Shaw Hospital · CNFirst Hospital of Jiaxing · CN

Funding

the Jiaxing Municipal Science and Technology Program and Project Management Measures 2017AY33029
6 · The paper itself

Abstract

backgroundBronchopleural fistula (BPF) is a relatively rare complication after various types of pulmonary resection. The double-sided mushroom-shaped occluder (Amplatzer device, AD) has been gradually used for BPF blocking due to its reliable blocking effect. We have improved the existing AD implantation methods to facilitate clinical use and named the new approach Sheath-free method (SFM). The aim of the present report was to explore the reliability and advantages of the SFM in AD implantation.

methodsWe improved the existing implantation methods by abandoning the sheath of the AD and using the working channel of the bronchoscope to directly store or release the AD without general anesthesia, rigid bronchoscopy, fluoroscopy, or bronchography. A total of 6 patients (5 men and 1 woman, aged 66.67 ± 6.19 years [mean ± SD]) had BPF blocking and underwent the SFM in AD implantation.

resultsAD implantation was successfully performed in all 6 patients with the SFM, 4 persons had a successful closure of the fistula, one person died after few days and one person did not have a successful closure of the fistula. The average duration of operation was 16.17 min (16.17 ± 4.67 min [mean ± SD]). No patients died due to operation complications or BPF recurrence. The average follow-up time was 13.2 months (range 10-17 months).

conclusionWe observed that the SFM for AD implantation-with accurate device positioning and a clear field of vision-is efficient and convenient. The AD is effective in BPF blocking, and could contribute to significantly improved symptoms of patients.

Indexed as

Septal Occluder DeviceAgedBronchial FistulaFemaleHumansMaleMiddle AgedPleural DiseasesProsthesis ImplantationRespiratory Tract FistulaAmplatzer devicesBronchopleural fistulaBronchoscopyPulmonary interventionSheath-free method

Identifiers

PMID33902515
PMCPMC8077945
OpenAlexW3106708533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.