Evidence map›Paper›PMID 33901230›Full record

ArticlePloS one2021

Sub-millimetre resolution laminar fMRI using Arterial Spin Labelling in humans at 7 T.

Sriranga Kashyap, Dimo Ivanov, Martin Havlicek, Laurentius Huber, Benedikt A Poser, Kâmil Uludağ

Erratum issuedAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Insights into hippocampal perfusion using high-resolution, multi-modal 7T MRI.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Sriranga KashyapDepartment of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.ORCID 0000-0003-0307-9773
Dimo IvanovDepartment of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.
Martin HavlicekDepartment of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.
Laurentius HuberDepartment of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.ORCID 0000-0002-3291-2202
Benedikt A PoserDepartment of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, The Netherlands.ORCID 0000-0001-8190-4367
Kâmil UludağCenter for Neuroscience Imaging Research, Institute for Basic Science, Sungkyunkwan University, Suwon, South Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Laminar fMRI at ultra-high magnetic field strength is typically carried out using the Blood Oxygenation Level-Dependent (BOLD) contrast. Despite its unrivalled sensitivity to detecting activation, the BOLD contrast is limited in its spatial specificity due to signals stemming from intra-cortical ascending and pial veins. Alternatively, regional changes in perfusion (i.e., cerebral blood flow through tissue) are colocalised to neuronal activation, which can be non-invasively measured using Arterial Spin Labelling (ASL) MRI. In addition, ASL provides a quantitative marker of neuronal activation in terms of perfusion signal, which is simultaneously acquired along with the BOLD signal. However, ASL for laminar imaging is challenging due to the lower SNR of the perfusion signal and higher RF power deposition i.e., specific absorption rate (SAR) of ASL sequences. In the present study, we present for the first time in humans, isotropic sub-millimetre spatial resolution functional perfusion images using Flow-sensitive Alternating Inversion Recovery (FAIR) ASL with a 3D-EPI readout at 7 T. We show that robust statistical activation maps can be obtained with perfusion-weighting in a single session. We observed the characteristic BOLD amplitude increase towards the superficial laminae, and, in apparent discrepancy, the relative perfusion profile shows a decrease of the amplitude and the absolute perfusion profile a much smaller increase towards the cortical surface. Considering the draining vein effect on the BOLD signal using model-based spatial "convolution", we show that the empirically measured perfusion and BOLD profiles are, in fact, consistent with each other. This study demonstrates that laminar perfusion fMRI in humans is feasible at 7 T and that caution must be exercised when interpreting BOLD signal laminar profiles as direct representation of the cortical distribution of neuronal activity.

Indexed as

Magnetic Resonance ImagingSpin LabelsAdultBrainBrain MappingComputer SimulationHumansOxygenPerfusionSignal Processing, Computer-AssistedOxygenSpin Labels

Identifiers

PMID33901230
PMCPMC8075193

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.