Evidence map›Paper›PMID 33899380›Full record

ArticleJournal of biomedical optics2021

Terahertz spectroscopy analysis of human corneal sublayers.

Lin Ke, Qing Yang Steve Wu, Nan Zhang, Zaifeng Yang, Erica Pei Wen Teo, Jodhbir S Mehta, Yu-Chi Liu

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Lin KeInstitute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore.
Qing Yang Steve WuInstitute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore.
Nan ZhangInstitute of Materials Research and Engineering, Agency for Science, Technology and Research, Singapore.
Zaifeng YangInstitute of High Performance Computing, Agency for Science, Technology and Research, Singapore.
Erica Pei Wen TeoSingapore Eye Research Institute, Singapore.
Jodhbir S MehtaSingapore Eye Research Institute, Singapore.
Yu-Chi LiuSingapore Eye Research Institute, Singapore.
Institute of Materials Research and Engineering · SGAgency for Science, Technology and Research · SGDuke-NUS Medical School · SGSingapore Eye Research Institute · SGSingapore National Eye Center · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceCorneal diseases is a major cause of reversible blindness in the world. Monitoring the progression of human corneal edema or corneal scarring to prevent the disease entering into the end stage is crucial.

aimWe present a method for sensing human corneal composition at different depths, namely focused on the epithelium and stromal layer, using high-sensitivity terahertz (THz) broadband spectroscopy. APPROACH: From the proposed methodology, the THz temporal and absorption spectra of human corneas at different edema stages have been studied. THz wave signals were collected from the direct reflection and four other collection points along the THz wave propagation direction as reviewed from the simulation THz electrical field.

resultOur results show that the epithelium layer acts as a good barrier to maintain hydration level of the stroma, and the quality of the epithelium can be used to predict the level of corneal swelling in corneal edema. At the detection points near to the incident point, the THz frequency spectra demonstrated interference oscillation behavior. At the final edema observing time, results showed that the epithelium lose its barrier properties. The intactness of the epithelium can be used to predict the edema severity in the final stage. When the detection points are further away from the incident point, the THz spectra are believed to contain information from stromal layer. Stromal absorption spectra demonstrated correlation with optical coherence tomography thickness results.

conclusionThe hydration concentration from stromal layer was further quantitatively calculated. At the end of the experiment, all the corneal hydration levels reach to the same value which shows that the edema hydration has reached maximum saturation. The information of individual sublayers of the cornea is obtained by characterizing noninvasively with the use of THz spectroscopy. To our knowledge, this is the first report of using THz for noninvasive characterization of sublayers of the cornea.

Indexed as

Corneal DiseasesCorneal InjuriesTerahertz SpectroscopyCorneaEdemaHumanscorneaedemahydrationnoninvasivespectroscopyterahertz

Identifiers

PMID33899380
PMCPMC8071781
OpenAlexW3157691508

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.