Evidence map›Paper›PMID 33899126›Full record

ArticleInternational journal of implant dentistry2021

Does the macro design of an implant affect the accuracy of template-guided implantation? A prospective clinical study.

Sigmar Schnutenhaus, Cornelia Edelmann, Heike Rudolph

Abstract read
In one paragraph

Article in International journal of implant dentistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Observational
  10. Review
  11. Article
  12. Article
  13. [Accuracy of computer-guided oral implant placement and influencing factors].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2022
    Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sigmar SchnutenhausZentrum für Zahnmedizin Dr. Schnutenhaus MVZ GmbH [Center for Dentistry, Dr. Schnutenhaus Community Health Center (CHC) GmbH], Breiter Wasmen 10, 78247, Hilzingen, Germany. info@schnutenhaus.de.ORCID 0000-0003-3593-7074
Cornelia EdelmannZentrum für Zahnmedizin Dr. Schnutenhaus MVZ GmbH [Center for Dentistry, Dr. Schnutenhaus Community Health Center (CHC) GmbH], Breiter Wasmen 10, 78247, Hilzingen, Germany.
Heike RudolphClinic for Dental Prosthetics, Center for Dental, Oral and Maxillofacial, Ulm University, Albert-Einstein-Allee 11, 89081, Ulm, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAn implant prosthesis aims to ensure the best possible rehabilitation of function and esthetics following tooth loss. Template-guided insertion is used to achieve an optimal position of the implant with regard to prosthetic restorability, bone availability, and condition of the surrounding soft tissues. The accuracy of template-guided implant placement is subject to various influencing factors. The clinically achievable accuracy depending on the macro design of the implant body was investigated in this prospective clinical study. MATERIAL AND

methodsIn this prospective clinical study, 20 implants were placed in 20 patients. The implant had a pronounced conical outer geometry (Conelog ProgressiveLine, Camlog Wimsheim, Germany). Data from a study using an implant with a distinct cylindrical outer geometry were used as a comparison group (Conelog ScrewLine, Camlog, Wimsheim, Germany). The clinically achieved implant position was compared with the planned position.

resultsThe evaluation of the two-dimensional deviations in direction resulted in the following mean values (standard deviation) at the shoulder: 0.42 mm (0.33) in the buccolingual direction, 0.27 mm (0.25) in the mesiodistal direction, and 0.68 mm (0.55) in the apicocoronal direction. The mean angular deviation was 4.1° (2.3). The three-dimensional (3D) deviation was 0.94 mm (0.53) at the shoulder and 1.36 mm (0.62) at the apex of the implant. Significant differences between implants with different macro designs were found in the apicocoronal direction. In connection to this, a significant 3D deviation was found at the implant shoulder.

conclusionsSignificant differences in height were found between the groups. The study had shown that the macro design of an implant has no influence on accuracy in all other directions. Overall, the implants showed a high level of accuracy and a low variation in values. The values were in the range determined by the template-guided insertion system in numerous other investigations. This provides good predictability of prosthetic rehabilitation.

trial registrationGerman Register for Clinical Studies (DRKS-ID: DRKS000018939 ). Date of registration: November 11, 2019.

Indexed as

Cone-Beam Computed TomographySurgery, Computer-AssistedComputer-Aided DesignHumansProspective StudiesProstheses and ImplantsAccuracyCBCTComputer-assisted surgeryComputer-guided surgeryDental implantImplant designSleeve

Identifiers

PMID33899126
PMCPMC8071785

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked