ArticlePhysics and imaging in radiation oncology2021

Determination of acceptance criteria for geometric accuracy of magnetic resonance imaging scanners used in radiotherapy planning.

Henna Kavaluus, Katri Nousiainen, Sampsa Kaijaluoto, Tiina Seppälä, Kauko Saarilahti, Mikko Tenhunen

Open access · goldAbstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. AAPM medical physics practice guideline 13.a: HDR brachytherapy, part A.Journal of applied clinical medical physics · 2023
    Guideline
  2. Article
  3. Article
  4. Article
  5. Article
  6. Motion modeling from 4D MR images of liver simulating phantom.Journal of applied clinical medical physics · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Henna KavaluusRadiation and Nuclear Safety Authority, STUK, Laippatie 4, FI-00880 Helsinki, Finland.
Katri NousiainenRadiation and Nuclear Safety Authority, STUK, Laippatie 4, FI-00880 Helsinki, Finland.
Sampsa KaijaluotoRadiation and Nuclear Safety Authority, STUK, Laippatie 4, FI-00880 Helsinki, Finland.
Tiina SeppäläHUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland.
Kauko SaarilahtiHUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland.
Mikko TenhunenHUS Cancer Center, Helsinki University Hospital and University of Helsinki, P.O. Box 180, FI-00029 Helsinki, Finland.
Helsinki University Hospital · FIRadiation and Nuclear Safety Authority · FI

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeMagnetic resonance imaging is increasingly used in radiotherapy planning; yet, the performance of the utilized scanners is rarely regulated by any authority. The aim of this study was to determine the geometric accuracy of several magnetic resonance imaging scanners used for radiotherapy planning, and to establish acceptance criteria for such scanners. MATERIALS AND

methodsThe geometric accuracy of five different scanners was measured with three sequences using a commercial large-field-of-view phantom. The distortion magnitudes were determined in spherical volumes around the scanner isocenter and in cylindrical volumes along scanner

resultsFor all scanners and sequences except one, the mean and median distortion magnitude was <1 mm and <2 mm in spherical volumes with diameters of 400 mm and 500 mm, respectively. For all sequences maximum distortion was <2 mm in spherical volume with diameter of 300 mm. The mean standard deviation of marker-by-marker distortion magnitudes over repeated acquisitions was ≤0.6 mm with both tested sequences.

conclusionsAll tested scanners were geometrically accurate for their current use in radiotherapy planning. The acceptance criteria of geometric accuracy for regulatory inspections of a supervising authority could be set according to these results.

Indexed as

Magnetic resonance imagingQuality assuranceRadiotherapy planningRegulatory inspections