Evidence map›Paper›PMID 33898688›Full record

ArticlePractical laboratory medicine2021

Performance evaluation of five lipoprotein(a) immunoassays on the Roche cobas c501 chemistry analyzer.

Sara P Wyness, Jonathan R Genzen

Open access · goldAbstract read
In one paragraph

Article in Practical laboratory medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Serum lipoprotein(a) and bioprosthetic aortic valve degeneration.European heart journal. Cardiovascular Imaging · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Sara P WynessARUP Institute of Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT, 84108, USA.
Jonathan R GenzenARUP Institute of Clinical and Experimental Pathology, 500 Chipeta Way, Salt Lake City, UT, 84108, USA.
ARUP Laboratories (United States) · USUniversity of Utah · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesMeasurement of lipoprotein(a) [Lp(a)] is used in risk assessment of atherosclerotic cardiovascular disease (ASCVD). The aim of the current study was to evaluate performance characteristic of five different Lp(a) assays using the cobas c501 (Roche Diagnostics) analyzer. DESIGN AND

methodsLp(a) was measured using five Lp(a) assays (Diazyme, Kamiya, MedTest, Randox, and Roche) configured to mg/dL units. Assays from Diazyme and Kamiya were also configured using nmol/L units in separate experiments. Studies included sensitivity, imprecision, linearity, method comparison, and evaluation of healthy subjects. Imprecision (intra-day, 20 replicates; inter-day, duplicates twice daily for five days) and linearity were evaluated using patient pools. Linearity assessed a minimum of five patient splits spanning the analytical measurement range (AMR). Method comparison used 80 residual serum samples. Specimens from 120 self-reported healthy subjects (61 females / 59 males) were also tested. Method comparison for two assays in nmol/L units was conducted using 96 residual serum samples.

resultsAssay sensitivities met all manufacturer claims. Imprecision studies demonstrated %CVs ranging from 2.5 to 5.2% for the low pool (average concentration from 7.3 to 12.4 ​mg/dL); high pool %CVs ranged from 0.8 to 3.0% (average concentrations from 31.5-50.2 ​mg/dL). Linearity was confirmed for all assays. Variation in accuracy was observed when comparing results to an all method average. Lp(a) results were higher in females versus males in self-reported healthy subjects.

conclusionsAll assays performed according to manufacturer described performance characteristics, although differences were observed across Lp(a) assays tested when compared to an all method average.

Indexed as

AMR, analytical measurement rangeapo(a), apolipoprotein(a)apoB-100, apolipoprotein B-100ASCVD, antherosclerotic cardiovascular diseaseAtherosclerotic cardiovascular diseaseCV, coefficient of variationELISA, enzyme linked immunosorbent assayHarmonizationIFCC, International Federation of Clinical ChemistryIFE, immunofixation electrophoresisKIV2, kringle-4 type 2LDL, low density lipoproteinLipidsLipoproteinLipoprotein(a)Lp(a), lipoprotein(a)NLMDRL, Northwest Lipid Metabolism and Diabetes Research LaboratoriesR, correlation coefficientStandardizationVNTR, variable number of tandem repeat

Identifiers

PMID33898688
PMCPMC8056269
OpenAlexW3137039362

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.