Evidence map›Paper›PMID 33898249›Full record

ArticleJournal of orthopaedic translation2021

A novel three-dimensional volumetric method to measure indirect decompression after percutaneous cement discoplasty.

Peter Endre Eltes, Laszlo Kiss, Ferenc Bereczki, Zsolt Szoverfi, Chloé Techens, Gabor Jakab, Benjamin Hajnal, Peter Pal Varga, Aron Lazary

Abstract read
In one paragraph

Article in Journal of orthopaedic translation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Biomechanical consequences of cement discoplasty: AnFrontiers in bioengineering and biotechnology · 2022
    Article
  7. AnFrontiers in bioengineering and biotechnology · 2022
    Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Peter Endre EltesIn Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Laszlo KissIn Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Ferenc BereczkiIn Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Zsolt SzoverfiNational Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Chloé TechensBiomechanics Lab, Department of Industrial Engineering, Alma Mater Studiorum, Universita di Bologna, Italy.
Gabor JakabNational Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Benjamin HajnalIn Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Peter Pal VargaNational Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Aron LazaryDepartment of Spine Surgery, Semmelweis University, Budapest, Hungary.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePercutaneous cement discoplasty (PCD) is a minimally invasive surgical option to treat patients who suffer from the consequences of advanced disc degeneration. As the current two-dimensional methods can inappropriately measure the difference in the complex 3D anatomy of the spinal segment, our aim was to develop and apply a volumetric method to measure the geometrical change in the surgically treated segments.

methodsProspective clinical and radiological data of 10 patients who underwent single- or multilevel PCD was collected. Pre- and postoperative CT scan-based 3D reconstructions were performed. The injected PMMA (Polymethylmethacrylate) induced lifting of the cranial vertebra and the following volumetric change was measured by subtraction of the geometry of the spinal canal from a pre- and postoperatively predefined cylinder. The associations of the PMMA geometry and the volumetric change of the spinal canal with clinical outcome were determined.

resultsChange in the spinal canal volume (ΔV) due to the surgery proved to be significant (mean ΔV = 2266.5 ± 1172.2 mm

conclusionThe developed method is accurate, reproducible and applicable for the analysis of any other spinal surgical method. The volume and surface area of the injected PMMA have a predictive power on the extent of the indirect spinal canal decompression. The larger the ΔV the higher clinical benefit was achieved with the PCD procedure. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: The developed method has the potential to be integrated into clinical software's to evaluate the efficacy of different surgical procedures based on indirect decompression effect such as PCD, anterior lumbar interbody fusion (ALIF), lateral lumbar interbody fusion (LLIF), oblique lumbar interbody fusion (OLIF), extreme lateral interbody fusion (XLIF). The intraoperative use of the method will allow the surgeon to respond if the decompression does not reach the desired level.

Indexed as

Computed tomographyIndirect foraminal decompressionMinimally invasive spine surgeryPatient-specific simulationPercutaneous cement discoplastyThree-dimensional volumetric measurements

Identifiers

PMID33898249
PMCPMC8050383

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.