Evidence map›Paper›PMID 33896201›Full record

ArticlePhilosophical transactions. Series A, Mathematical, physical, and engineering sciences2021

Super-resolution fluorescence microscopy by line-scanning with an unmodified two-photon microscope.

Christian Pilger, Jakub Pospíšil, Marcel Müller, Martin Ruoff, Martin Schütte, Heinrich Spiecker, Thomas Huser

Open access · hybridAbstract read
In one paragraph

Article in Philosophical transactions. Series A, Mathematical, physical, and engineering sciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Super-resolution microscopy: a brief history and new avenues.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Christian PilgerBiomolecular Photonics, Department of Physics, University of Bielefeld, Bielefeld, Germany.
Jakub PospíšilBiomolecular Photonics, Department of Physics, University of Bielefeld, Bielefeld, Germany.
Marcel MüllerBiomolecular Photonics, Department of Physics, University of Bielefeld, Bielefeld, Germany.
Martin RuoffLaVision BioTec GmbH, Astastraße 14, 33617 Bielefeld, Germany.
Martin SchütteLaVision BioTec GmbH, Astastraße 14, 33617 Bielefeld, Germany.
Heinrich SpieckerLaVision BioTec GmbH, Astastraße 14, 33617 Bielefeld, Germany.
Thomas HuserBiomolecular Photonics, Department of Physics, University of Bielefeld, Bielefeld, Germany.
Bielefeld University · DELaVision (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fluorescence-based microscopy as one of the standard tools in biomedical research benefits more and more from super-resolution methods, which offer enhanced spatial resolution allowing insights into new biological processes. A typical drawback of using these methods is the need for new, complex optical set-ups. This becomes even more significant when using two-photon fluorescence excitation, which offers deep tissue imaging and excellent z-sectioning. We show that the generation of striped-illumination patterns in two-photon laser scanning microscopy can readily be exploited for achieving optical super-resolution and contrast enhancement using open-source image reconstruction software. The special appeal of this approach is that even in the case of a commercial two-photon laser scanning microscope no optomechanical modifications are required to achieve this modality. Modifying the scanning software with a custom-written macro to address the scanning mirrors in combination with rapid intensity switching by an electro-optic modulator is sufficient to accomplish the acquisition of two-photon striped-illumination patterns on an sCMOS camera. We demonstrate and analyse the resulting resolution improvement by applying different recently published image resolution evaluation procedures to the reconstructed filtered widefield and super-resolved images. This article is part of the Theo Murphy meeting issue 'Super-resolution structured illumination microscopy (part 1)'.

Indexed as

AlgorithmsAnimalsConvallariaImage Processing, Computer-AssistedKidneyMiceMicroscopy, Fluorescence, MultiphotonOptical DevicesOptical PhenomenaSoftwarelaser scanning fluorescence microscopymulti-photon fluorescence excitationSIMstructured illumination microscopysuper-resolution optical microscopy

Identifiers

PMID33896201
PMCPMC8072199
OpenAlexW3157202573

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.