Evidence map›Paper›PMID 33895658›Full record

ArticleJournal of biomechanics2021

Hemodynamic performance limits of the neonatal Double-Lumen cannula.

Reza Rasooli, Muhammad Jamil, Mohammad Rezaeimoghaddam, Yahya Yıldız, Ece Salihoglu, Kerem Pekkan

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Impact of altered vena cava flow rates on right atrium flow characteristics.Journal of applied physiology (Bethesda, Md. : 1985) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Reza RasooliMechanical Engineering, Koc University, Turkey.
Muhammad JamilMechanical Engineering, Koc University, Turkey.
Mohammad RezaeimoghaddamMechanical Engineering, Koc University, Turkey.
Yahya YıldızSchool of Medicine, Medipol University, Turkey.
Ece SalihogluSchool of Medicine, Biruni University, Turkey.
Kerem PekkanMechanical Engineering, Koc University, Turkey. Electronic address: kpekkan@ku.edu.tr.
Koç University · TRBiruni University · TRIstanbul Medipol University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Venovenous extracorporeal membrane oxygenation (VV-ECMO) is the preferred surgical intervention for patients suffering from severe cardiorespiratory failure, also encountered in SARS-Cov-2 management. The key component of VV-ECMO is the double-lumen cannula (DLC) that enables single-site access. The biofluid dynamics of this compact device is particularly challenging for neonatal patients due to high Reynolds numbers, tricuspid valve location and right-atrium hemodynamics. In this paper we present detailed findings of our comparative analysis of the right-atrial hemodynamics and salient design features of the 13Fr Avalon Elite DLC (as the clinically preferred neonatal cannula) with the alternate Origen DLC design, using experimentally validated computational fluid dynamics. Highly accurate 3D-reconstructions of both devices were obtained through an integrated optical coherence tomography and micro-CT imaging approach. Both cannula configurations displayed complex flow structures inside the atrium, superimposed over predominant recirculation regimes. We found that the Avalon DLC performed significantly better than the Origen alternative, by capturing 80% and 94% of venous blood from the inferior and superior vena cavae, respectively and infusing the oxygenated blood with an efficiency of more than 85%. The micro-scale geometric design features of the Avalon DLC that are associated with superior hemodynamics were investigated through 14 parametric cannula configurations. These simulations showed that the strategic placement of drainage holes, the smooth infusion blood stream diverter and efficient distribution of the venous blood capturing area between the vena cavae are associated with robust blood flow performance. Nevertheless, our parametric results indicate that there is still room for further device optimization beyond the performance measurements for both Avalon and Origen DLC in this study. In particular, the performance envelope of malpositioned cannula and off-design conditions require additional blood flow simulations for analysis.

Indexed as

COVID-19Extracorporeal Membrane OxygenationCannulaHemodynamicsHumansInfant, NewbornSARS-CoV-2Biofluid mechanicsCardiovascular devicesCongenital heart defectsHemodynamicsHemolysis and thrombogenicitymicro-CT

Identifiers

PMID33895658
PMCPMC9750623
OpenAlexW3152664737

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.