Evidence map›Paper›PMID 33895641›Full record

ArticleJournal of chromatography. A2021

A method for the analysis of 121 multi-class environmental chemicals in urine by high-performance liquid chromatography-tandem mass spectrometry.

Hongkai Zhu, Sridhar Chinthakindi, Kurunthachalam Kannan

Open access · greenAbstract read
In one paragraph

Article in Journal of chromatography. A, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 46 citations in OpenAlex.

  1. Article
  2. Observational
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Hongkai ZhuDepartment of Pediatrics and Department of Environmental Medicine, New York University School of Medicine, MSB 6-698, 550 1st Avenue, New York, NY 10016, United States.
Sridhar ChinthakindiDepartment of Pediatrics and Department of Environmental Medicine, New York University School of Medicine, MSB 6-698, 550 1st Avenue, New York, NY 10016, United States.
Kurunthachalam KannanDepartment of Pediatrics and Department of Environmental Medicine, New York University School of Medicine, MSB 6-698, 550 1st Avenue, New York, NY 10016, United States. Electronic address: kurunthachalam.kannan@nyulangone.org.
New York University · US

Funding

Wadsworth Center's Human Health and Exposure Analysis Resource (WC-HHEAR)U2CES026542 · NIEHS · WADSWORTH CENTER · PI KANNAN, KURUNTHACHALAM, KANNAN, KURUNTHACHALAM · 2015 to 2025
$15.6M
NIEHS NIH HHS U2C ES026542
6 · The paper itself

Abstract

Biomonitoring of human exposure to environmental chemicals has gained momentum in recent years. Biomonitoring methods often include analysis of a single class of chemicals with similar chemical properties. In this study, we describe a method that involves solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and capable of measuring 121 environmental chemicals comprising plasticizers (PMs; n = 45), environmental phenols (EPs; n = 45), and pesticides (n = 31) through a single extraction of urine. Urine samples were incubated with 20 µL of β-glucuronidase/arylsulfatase (4000 units/mL urine) (from Helix pomatia) buffered at pH 5.5 for 2 h at 37 °C for optimal deconjugation conditions. We compared two extraction methods, namely liquid-liquid extraction and SPE, and the latter with ABS Elut NEXUS® cartridges was optimized to yield best extraction efficiencies. For increased resolution and chromatographic separation, two methods involving Ultra AQ C18® and Betasil™ C18® columns were used. The MS/MS analyses were performed under both negative and positive ionization modes. The optimized method yielded excellent intra- and inter-day variabilities (relative standard deviation: 0.40-11%) and satisfactory recoveries (80-120%) for >95% of the analytes. The limits of detection were ≤ 0.1 ng/mL for 101 analytes and between 0.1 and 1.0 ng/mL for 18 analytes. The optimized SPE LC-MS/MS method was validated through the analysis of standard reference materials and proficiency test urine samples and further applied in the analysis of 21 real urine samples to demonstrate simultaneous determination of 121 environmental chemicals in urine samples.

Indexed as

Chromatography, High Pressure LiquidEnvironmental PollutantsHumansLimit of DetectionPesticidesPhenolsPlasticizersSolid Phase ExtractionTandem Mass SpectrometryUrinalysisEnvironmental PollutantsPesticidesPhenolsPlasticizersEndocrine disruptorsExposomeHuman biomonitoringLC-MS/MSMulti-class methodUrine

Identifiers

PMID33895641
PMCPMC8106663
OpenAlexW3153186878

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.