Effect of synthetic bone replacement material of different size on shear stress resistance within impacted native and thermodisinfected cancellous bone: an in vitro femoral impaction bone grafting model.

C Fölsch, P Sahm, C A Fonseca Ulloa, G A Krombach, M Kampschulte, M Rickert, A Pruss, A Jahnke

Open access · hybridAbstract read
In one paragraph

Article in Cell and tissue banking, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

C FölschDepartment of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Gießen, Germany. christian.foelsch@ortho.med.uni-giessen.de.
P SahmLaboratory of Biomechanics, Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 29, 35392, Giessen, Germany.
C A Fonseca UlloaLaboratory of Biomechanics, Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 29, 35392, Giessen, Germany.
G A KrombachDepartment of Diagnostic and Interventional Radiology, Laboratory for Experimental Radiology, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Giessen, Germany.
M KampschulteDepartment of Diagnostic and Interventional Radiology, Laboratory for Experimental Radiology, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Giessen, Germany.
M RickertDepartment of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 33, 35392, Gießen, Germany.
A PrussInstitute of Transfusion Medicine, University Tissue Bank, Charité University Medical School, Charitéplatz 1, 10117, Berlin, Germany.
A JahnkeLaboratory of Biomechanics, Department of Orthopaedic Surgery, Justus-Liebig-University Medical School, Klinikstrasse 29, 35392, Giessen, Germany.
Justus-Liebig-Universität Gießen · DEMSB Medical School Berlin · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Antibiotic carrier particles of variable size might influence mechanic properties within impacted thermodisinfected and native cancellous bone different. Herafill®G containing calciumsulfate and calciumcarbonate provides high local concentrations of gentamicin being important for revision surgery in infected joint replacements. Native and thermodisinfected cancellous bone derived from 6 to 7 months old piglets was used for in vitro impaction bone grafting and supplemented each with Herafill®G granules of two different sizes. Micromovement of implants related to shear force was measured in 29 specimens distributed in 6 groups. Thermodisinfected cancellous bone revealed a significant higher shear force resistance than native bone with a mean difference of 423.8 mdeg/Nm (p < 0.001) ranging within 95% confidence interval from 181.5 to 666.0 mdeg/Nm. Adding small granules to thermodisinfected bone did not reduce shear force resistance significantly since adding large granules to native bone improved it by 344.0 mdeg/Nm (p < 0.003). Shear force resistance was found higher at the distal region of the implant compared to a proximal point of measurement throughout all specimens. Less impaction impulses were necessary for thermodisinfected bone. Thermodisinfected cancellous bone might achieve a higher degree of impaction compared with native bone resulting in increased resistance against shear force since impaction was found increased distally. Supplementation of thermodisinfected bone with small granules of Herafill®G might be considered for application of local antibiotics. Large granules appeared more beneficial for supplementation of native bone. Heterogeneity of bone graft and technical aspects of the impaction procedure have to be considered regarding the reproducibility of femoral impaction bone grafting.

Indexed as

Arthroplasty, Replacement, HipBone SubstitutesAnimalsBone TransplantationCancellous BoneFemurReoperationReproducibility of ResultsSwineBone SubstitutesAllogeneic boneBone bankBone reconstructionFemoral impaction bone graftingInfection joint replacementLocal antibiotic therapyThermodisinfection

Identifiers

PMID33893901
PMCPMC8558171
OpenAlexW3156515947

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.