Design of a force-measuring setup for colorectal compression anastomosis and first ex-vivo results.

Jana Steger, Isabella Patzke, Maximilian Berlet, Stefanie Ficht, Markus Eblenkamp, Petra Mela, Dirk Wilhelm

Abstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jana StegerResearch Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany. jana.steger@tum.de.ORCID http://orcid.org/0000-0002-5576-3262
Isabella PatzkeResearch Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany.
Maximilian BerletResearch Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany.
Stefanie FichtChair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany.
Markus EblenkampChair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany.
Petra MelaChair of Medical Materials and Implants, Department of Mechanical Engineering and Munich School of BioEngineering, Technical University of Munich, Munich, Germany.
Dirk WilhelmResearch Group Minimally Invasive Interdisciplinary Therapeutical Intervention (MITI), Klinikum Rechts der Isar of Technical University of Munich, Munich, Germany.

Funding

Deutsche Forschungsgemeinschaft 386233407
6 · The paper itself

Abstract

purposeThe introduction of novel endoscopic instruments is essential to reduce trauma in visceral surgery. However, endoscopic device development is hampered by challenges in respecting the dimensional restrictions, due to the narrow access route, and by achieving adequate force transmission. As the overall goal of our research is the development of a patient adaptable, endoscopic anastomosis manipulator, biomechanical and size-related characterization of gastrointestinal organs are needed to determine technical requirements and thresholds to define functional design and load-compatible dimensioning of devices.

methodsWe built an experimental setup to measure colon tissue compression piercing forces. We tested 54 parameter sets, including variations of three tissue fixation configurations, three piercing body configurations (four, eight, twelve spikes) and insertion trajectories of constant velocities (5 mms

resultsThere was no statistically significant difference in insertion forces neither between the trajectory groups, nor for variation of tissue fixation configurations. However, we observed a statistically significant increase in insertion forces for increasing number of spikes. The maximum mean peak forces for four, eight and twelve spikes were 6.4 ± 1.5 N, 13.6 ± 1.4 N and 21.7 ± 5.8 N, respectively. The 5th percentile of specimen lumen diameters and pierced tissue thickness were 24.1 mm and 2.8 mm, and the 95th percentiles 40.1 mm and 4.8 mm, respectively.

conclusionThe setup enabled reliable biomechanical characterization of colon material, on the base of which design specifications for an endoscopic anastomosis device were derived. The axial implant closure unit must enable axial force transmission of at least 28 N (22 ± 6 N). Implant and applicator diameters must cover a range between 24 and 40 mm, and the implant gap, compressing anastomosed tissue, between 2 and 5 mm.

Indexed as

Neoplasms, ExperimentalAnastomosis, SurgicalAnimalsBiomechanical PhenomenaColonoscopyColorectal NeoplasmsDigestive System Surgical ProceduresPressureRectumSwineAnastomosisColonEndoscopyForcesImplantsPiercing

Identifiers

PMID33891254
PMCPMC8295116

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.