Evidence map›Paper›PMID 33889817›Full record

ArticleiScience2021

Comparison of applied torque and energy conversion efficiency between rotational triboelectric nanogenerator and electromagnetic generator.

Shaohang Xu, Xianpeng Fu, Guoxu Liu, Tong Tong, Tianzhao Bu, Zhong Lin Wang, Chi Zhang

Abstract read
In one paragraph

Article in iScience, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Nanoionics from Biological to Artificial Systems: An Alternative Beyond Nanoelectronics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2022
    Review
  7. Review
  8. Review
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shaohang XuCAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China.
Xianpeng FuCAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China.
Guoxu LiuCAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China.
Tong TongCAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China.
Tianzhao BuCAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China.
Zhong Lin WangCAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China.
Chi ZhangCAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 101400, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Triboelectric nanogenerator (TENG) is regarded as an equally important mechanical energy harvesting technology as electromagnetic generator (EMG). Here, the input mechanical torques and energy conversion efficiencies of the rotating EMG and TENG are systematically measured, respectively. At constant rotation rates, the input mechanical torque of EMG is balanced by the friction resisting torque and electromagnetic resisting torque, which increases with the increasing rotation rate due to Ampere force. While the input mechanical torque of TENG is balanced by the friction resisting torque and electrostatic resisting torque, which is nearly constant at different rotation rates. The energy conversion efficiency of EMG increases with the increasing input mechanical power, while that of the TENG remains nearly constant. Compared with the EMG, the TENG has a higher conversion efficiency at a low input mechanical power, which demonstrates a remarkable merit of the TENG for efficiently harvesting weak ambient mechanical energy.

Indexed as

Electromagnetic FieldEnergy ResourcesEnergy SystemsNanostructure

Identifiers

PMID33889817
PMCPMC8050373

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390