Evidence map›Paper›PMID 33886607›Full record

ArticlePloS one2021

Image-derived mean velocity measurement for prediction of coronary flow reserve in a canonical stenosis phantom using magnetic particle imaging.

Robert Siepmann, Henning Nilius, Florian Mueller, Katrin Mueller, Claudio Luisi, Seyed Mohammadali Dadfar, Marcel Straub, Volkmar Schulz, Sebastian Daniel Reinartz

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Robert SiepmannPhysics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.ORCID 0000-0002-4608-5180
Henning NiliusPhysics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Florian MuellerPhysics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Katrin MuellerPhysics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Claudio LuisiApplied Medical Engineering, RWTH Aachen University, Aachen, Germany.ORCID 0000-0001-7298-9864
Seyed Mohammadali DadfarExperimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.ORCID 0000-0001-8621-308X
Marcel StraubPhysics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Volkmar SchulzPhysics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Sebastian Daniel ReinartzDepartment of Diagnostic and Interventional Radiology, Uniklinikum Aachen, Aachen, Germany.
RWTH Aachen University · DEUniversitätsklinikum Aachen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAim of this study is to evaluate whether magnetic particle imaging (MPI) is capable of measuring velocities occurring in the coronary arteries and to compute coronary flow reserve (CFR) in a canonical phantom as a preliminary study.

methodsFor basic velocity measurements, a circulation phantom was designed containing replaceable glass tubes with three varying inner diameters, matching coronary-vessel diameters. Standardised boluses of superparamagnetic-iron-oxide-nanoparticles were injected and visualised by MPI. Two image-based techniques were competitively applied to calibrate the respective glass tube and to compute the mean velocity: full-duration-at-half-maximum (FDHM) and tracer dilution (TD) method. For CFR-calculation, four necessary settings of the circulation model of a virtual vessel with an inner diameter of 4 mm were generated using differently sized glass tubes and a stenosis model. The respective velocities in stenotic glass tubes were computed without recalibration.

resultsOn velocity level, comparison showed a good agreement (rFDHM = 0.869, rTD = 0.796) between techniques, preferably better for 4 mm and 6 mm inner diameter glass tubes. On CFR level MPI-derived CFR-prediction performed considerably inferior with a relative error of 20-44%.

conclusionsMPI has the ability to reliably measure coronary blood velocities at rest as well as under hyperaemia and therefore may be suitable for CFR calculation. Calibration-associated accuracy of CFR-measurements has to be improved substantially in further studies.

Indexed as

Blood Flow VelocityCoronary CirculationCoronary StenosisFractional Flow Reserve, MyocardialHemodynamicsHumansImage Processing, Computer-AssistedImaging, Three-DimensionalIn Vitro TechniquesMagnetic PhenomenaModels, CardiovascularPhantoms, Imaging

Identifiers

PMID33886607
PMCPMC8061921
OpenAlexW3155821807

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.