Evidence map›Paper›PMID 33885912›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2022

Validity and reliability of a wearable-controlled serious game and goniometer for telemonitoring of wrist fracture rehabilitation.

Henriëtte A W Meijer, Maurits Graafland, Miryam C Obdeijn, Marlies P Schijven, J Carel Goslings

Open access · hybridAbstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Henriëtte A W MeijerDepartment of Surgery, Amsterdam Movement Sciences, Amsterdam UMC, Location Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands. h.a.meijer@amsterdamumc.nl.ORCID http://orcid.org/0000-0002-2342-9446
Maurits GraaflandDepartment of Surgery, Amsterdam UMC, Location Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
Miryam C ObdeijnDepartment of Plastic, Reconstructive and Hand Surgery, Amsterdam Movement Sciences, Amsterdam UMC, Location Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
Marlies P SchijvenDepartment of Surgery, Amsterdam Gastroenterology and Metabolism, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands.
J Carel GoslingsDepartment of Trauma Surgery, Onze Lieve Vrouwe Gasthuis, Jan Tooropstraat 164, 1061 AE, Amsterdam, The Netherlands.
Amsterdam UMC Location University of Amsterdam · NLAmsterdam University Medical Centers · NLOLVG · NL

Funding

Growing Games Program (Dutch Game Garden, iMMovator, Dutch Games Association and the Economic Board Utrecht) CB00018
6 · The paper itself

Abstract

purposeTo determine the validity of wrist range of motion (ROM) measurements by the wearable-controlled ReValidate! wrist-rehabilitation game, which simultaneously acts as a digital goniometer. Furthermore, to establish the reliability of the game by contrasting ROM measurements to those found by medical experts using a universal goniometer.

methodsAs the universal goniometer is considered the reference standard, inter-rater reliability between surgeons was first determined. Internal validity of the game ROM measurements was determined in a test-retest setting with healthy volunteers. The reliability of the game was tested in 34 patients with a restricted range of motion, in whom the ROM was measured by experts as well as digitally. Intraclass-correlation coefficients (ICCs) were determined and outcomes were analyzed using Bland-Altman plots.

resultsInter-rater reliability between experts using a universal goniometer was poor, with ICCs of 0.002, 0.160 and 0.520. Internal validity testing of the game found ICCs of - 0.693, 0.376 and 0.863, thus ranging from poor to good. Reliability testing of the game compared to medical expert measurements, found that mean differences were small for the flexion-extension arc and the radial deviation-ulnar deviation arc.

conclusionThe ReValidate! game is a reliable home-monitoring device digitally measuring ROM in the wrist. Interestingly, the test-retest reliability of the serious game was found to be considerably higher than the inter-rater reliability of the reference standard, being healthcare professionals using a universal goniometer. TRIAL REGISTRATION NUMBER: (internal hospital registration only) MEC-AMC W17_003 #17.015.

Indexed as

Wearable Electronic DevicesWristHumansRange of Motion, ArticularReproducibility of ResultsWrist JointDistal radius fractureGoniometerRange of motionRehabilitationSerious gameTelemonitoring

Identifiers

PMID33885912
PMCPMC9001232
OpenAlexW3156134878

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked