Evidence map›Paper›PMID 33883631›Full record

ArticleScientific reports2021

Electrocardiographic and electrophysiological characteristics of idiopathic ventricular arrhythmias originating from the vicinity of tricuspid annulus.

Manli Yu, Liangliang Hou, Hang Yu, Junwei Ge, Pan Li, Zhifu Guo, Xinmiao Huang, Xianxian Zhao, Jiang Cao, Songqun Huang

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Value of the 12-lead ECG to localize the origin of ventricular tachycardia.Herzschrittmachertherapie & Elektrophysiologie · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Manli Yu *Department of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China.
Liangliang Hou *Department of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China.
Hang Yu *Department of Emergency, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China.
Junwei GeDepartment of Cardiovasology, Shanghai Seventh People's Hospital, Shanghai, 200433, China.
Pan LiDepartment of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China.
Zhifu GuoDepartment of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China.
Xinmiao HuangDepartment of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China.
Xianxian ZhaoDepartment of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China.
Jiang CaoDepartment of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China. chrfca@163.om.
Songqun HuangDepartment of Cardiovasology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China. huangsongqun@smmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrocardiographic and electrophysiological characteristics of VAs originating from the vicinity of the TA are not fully understood. Hence, 104 patients (mean age 52.6 ± 17.9 years; 62 male) with VAs originating from the vicinity of the TA were enrolled. After electrophysiological evaluation and ablation, data were compared among those patients. The ECGs and the correction of the ECGs based on the long axis of the heart calculated from the chest X-Ray were also analyzed. VAs originating from the vicinity of TA had distinctive ECG characteristics that were useful for identifying the precise origin. Our localization algorithm adjusted by the angle between the cardiac long axis and the horizon was found to be accurate in predicting the exact ablation site in 92.3% (n = 96) cases. Logistic regression analysis showed fractionated electrograms, the magnitudes of the local atrial electrograms and a/V ratio were critical factors for successful ablation. Among the 104 patients with VAs, complete elimination could be achieved by RFCA in 96 patients (success rate 92.3%) during a follow-up period of 35.2 ± 19.6 months. This study suggests that the ablation site could be localized by ECG analysis adjusted by the angle between the cardiac long axis and the horizon. Fractionated electrograms, the magnitudes of the local atrial electrograms and a/V ratio were demonstrated to be critical factors for successful ablation.

Indexed as

AdolescentAdultAgedAged, 80 and overAlgorithmsCardiac ElectrophysiologyCatheter AblationElectrocardiographyElectrophysiological PhenomenaFemaleHeart Conduction SystemHeart VentriclesHumansMaleMiddle AgedTachycardia, Ventricular

Identifiers

PMID33883631
PMCPMC8060328

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.