ArticleScientific reports2021

Optical density based quantification of total haemoglobin concentrations with spectroscopic optical coherence tomography.

Carlos Cuartas-Vélez, Colin Veenstra, Saskia Kruitwagen, Wilma Petersen, Nienke Bosschaart

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Carlos Cuartas-VélezBiomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands. c.a.cuartasvelez@utwente.nl.
Colin VeenstraBiomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands.
Saskia KruitwagenBiomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands.
Wilma PetersenBiomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands.
Nienke BosschaartBiomedical Photonic Imaging Group, Faculty of Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Spectroscopic optical coherence tomography (sOCT) has emerged as a new possibility for non-invasive quantification of total haemoglobin concentrations [tHb]. Recently, we demonstrated that [tHb] measured in ex-vivo human whole-blood with a conventional sOCT system achieves a precision of 9.10 g/dL with a bias of 1.50 g/dL. This precision improved by acquiring data with a combination of focus tracking and zero-delay acquisition (FZA) that compensated for experimental limitations, increasing to 3.80 g/dL with a bias of 1.50 g/dL. Nevertheless, sOCT precision should improve at least to [Formula: see text] g/dL to be clinically relevant. Therefore, sOCT-based [tHb] determinations require the development of new analysis methods that reduce the variability of [tHb] estimations. In this work, we aim to increase sOCT precision by retrieving the [tHb] content from a numerical optimisation of the optical density (OD), while considering the blood absorption flattening effect. The OD-based approach simplifies previous two-step Lambert-Beer fitting approaches to a single step, thereby reducing errors during the fitting procedure. We validated our model with ex-vivo [tHb] measurements on flowing whole-blood samples in the clinical range (7-23 g/dL). Our results show that, with the new model, conventional sOCT can determine [tHb] with a precision of 3.09 g/dL and a bias of 0.86 g/dL compared to a commercial blood analyser. We present further precision improvement by combining the OD methodology with FZA, leading to a precision of 2.08 g/dL with a bias of 0.46 g/dL.

Indexed as

HemoglobinsHumansReproducibility of ResultsSpectrum AnalysisTomography, Optical CoherenceHemoglobins

Identifiers

PMID33883617
PMCPMC8060256

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.