Evidence map›Paper›PMID 33883543›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2021

External Screw-Threaded Traction Device Helps Optimize Finger Joint Mobility in Severe Stage III and IV Dupuytren Disease.

Raymund E Horch, Marweh Schmitz, Maria Kreuzer, Andreas Arkudas, Ingo Ludolph, Wibke Müller-Seubert

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Raymund E HorchDepartment of Plastic and Hand Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Marweh SchmitzDepartment of Plastic and Hand Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Maria KreuzerDepartment of Geriatric Medicine, Klinikum St. Marien Amberg, Amberg, Germany.
Andreas ArkudasDepartment of Plastic and Hand Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Ingo LudolphDepartment of Plastic and Hand Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Wibke Müller-SeubertDepartment of Plastic and Hand Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Erlangen, Germany.
Friedrich-Alexander-Universität Erlangen-Nürnberg · DEKlinikum St. Marien Amberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Treating advanced finger joint contractures from Dupuytren disease remains a challenge. We evaluated the effectiveness of a skeletal distraction device versus alternative treatment options. MATERIAL AND METHODS We analyzed the surgical treatment of contracted finger joints in stage III and stage IV Dupuytren's disease over a 10-year period. Data were obtained from inpatient and outpatient medical records, including postoperative clinical examinations and extended Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire scores. Complications of infection, postoperative pain, and wound healing disorders were recorded. RESULTS A total of 79 patients (83 hands) were assigned to 2 treatment groups. Patients in group 1 underwent an initial open transection of the main fibrous cord, Z-plasty, distraction with the Erlangen external distraction device, and fasciectomy. The distraction period was 13 to 81 days (mean 31 days). Group 2 underwent a conventional single-stage fasciectomy and arthrolysis. DASH scores and subjective patient satisfaction were lower in group 1 (20.7/33%) than in group 2 (10.3/50%). However, the staged approach of group 1 to treat proximal interphalangeal joint contractures in the long term (improvement >40%) was more effective than the approach of group 2 (>33%). Distraction device pin infections occurred in 20% of hands. Postoperative pain and complex regional pain syndrome type I occurred in 25% of hands in group 1 and 3% in group 2. CONCLUSIONS A screw thread driven external fixation device is useful in end-stage Dupuytren's finger joint contractures. It is indicated when joint contractures are advanced and simple arthrolysis is insufficient.

Indexed as

Equipment and SuppliesAdultAgedAged, 80 and overBone ScrewsDisease ProgressionDupuytren ContractureExternal FixatorsFemaleFinger JointHumansMaleMiddle AgedOrthopedic ProceduresPostoperative CareRange of Motion, Articular

Identifiers

PMID33883543
PMCPMC8078024
OpenAlexW3132336675

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.