Evidence map›Paper›PMID 33882909›Full record

ArticleBMC cancer2021

Clinically relevant dual probe difference specimen imaging (DDSI) protocol for freshly resected breast cancer specimen staining.

Broderick J House, Marcus J Kwon, Jasmin M Schaefer, Connor W Barth, Allison Solanki, Scott C Davis, Summer L Gibbs

Abstract read
In one paragraph

Article in BMC cancer, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Broderick J HouseBiomedical Engineering Department, Oregon Health & Science University, 2730 S Moody Ave, Mail Code: CL3SG, Portland, OR, 97201, USA.
Marcus J KwonBiomedical Engineering Department, Oregon Health & Science University, 2730 S Moody Ave, Mail Code: CL3SG, Portland, OR, 97201, USA.
Jasmin M SchaeferBiomedical Engineering Department, Oregon Health & Science University, 2730 S Moody Ave, Mail Code: CL3SG, Portland, OR, 97201, USA.
Connor W BarthBiomedical Engineering Department, Oregon Health & Science University, 2730 S Moody Ave, Mail Code: CL3SG, Portland, OR, 97201, USA.
Allison SolankiBiomedical Engineering Department, Oregon Health & Science University, 2730 S Moody Ave, Mail Code: CL3SG, Portland, OR, 97201, USA.
Scott C DavisThayer School of Engineering, Dartmouth College, Hanover, NH, 03755, USA.
Summer L GibbsBiomedical Engineering Department, Oregon Health & Science University, 2730 S Moody Ave, Mail Code: CL3SG, Portland, OR, 97201, USA. gibbss@ohsu.edu.

Funding

Multi-probe fluorescence imaging for rapid intra-operative tumor margin assessmentR01CA188491 · NCI · DARTMOUTH COLLEGE · PI DAVIS, SCOTT C · 2015 to 2019
$2.9M
NCI NIH HHS R01 CA188491
6 · The paper itself

Abstract

backgroundRe-excision rates following breast conserving surgery (BCS) remain as high as ~ 35%, with positive margins detected during follow-up histopathology. Additional breast cancer resection surgery is not only taxing on the patient and health care system, but also delays adjuvant therapies, increasing morbidity and reducing the likelihood of a positive outcome. The ability to precisely resect and visualize tumor margins in real time within the surgical theater would greatly benefit patients, surgeons and the health care system. Current tumor margin assessment technologies utilized during BCS involve relatively lengthy and labor-intensive protocols, which impede the surgical work flow.

methodsIn previous work, we have developed and validated a fluorescence imaging method termed dual probe difference specimen imaging (DDSI) to accurately detect benign and malignant tissue with direct correlation to the targeted biomarker expression levels intraoperatively. The DDSI method is currently on par with touch prep cytology in execution time (~ 15-min). In this study, the main goal was to shorten the DDSI protocol by decreasing tissue blocking and washing times to optimize the DDSI protocol to < 10-min whilst maintaining robust benign and malignant tissue differentiation.

resultsWe evaluated the utility of the shortened DDSI staining methodology using xenografts grown from cell lines with varied epidermal growth factor receptor (EGFR) expression levels, comparing accuracy through receiver operator characteristic (ROC) curve analyses across varied tissue blocking and washing times. An optimized 8-min DDSI methodology was developed for future clinical translation.

conclusionsSuccessful completion of this work resulted in substantial shortening of the DDSI methodology for use in the operating room, that provided robust, highly receptor specific, sensitive diagnostic capabilities between benign and malignant tissues.

Indexed as

Molecular ProbesAnimalsBreast NeoplasmsCell Line, TumorDiagnostic ImagingDisease Models, AnimalFemaleHumansMiceNeoplasm StagingStaining and LabelingMolecular ProbesBreast conserving surgeryDual probe difference specimen imagingFluorescence guided surgeryPaired agent imagingTumor margin assessment

Identifiers

PMID33882909
PMCPMC8059239

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.