Effect of treatment planning system parameters on beam modulation complexity for treatment plans with single-layer multi-leaf collimator and dual-layer stacked multi-leaf collimator.
Article in The British journal of radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 15 citations in OpenAlex.
- Dose accuracy evaluation of multi-leaf collimator modeling in single-isocenter multi-target stereotactic radiosurgery.Physics and imaging in radiation oncology · 2026Article
- A Multidimensional Assessment of the Aperture Shape Controller in VMAT for Ca Tongue: Implications for Plan Complexity and Quality Assurance.Asian Pacific journal of cancer prevention : APJCP · 2026Article
- Evaluating the trade-off between plan complexity, dosimetric accuracy, and treatment efficiency: Role of aperture shape controller settings in HyperArc for intracranial oligometastases.Precision radiation oncology · 2025Article
- Sensitivity and specificity of Monte Carlo based independent secondary dose computation for detecting modulation-related dose errors in intensity modulated radiotherapy.Zeitschrift fur medizinische Physik · 2025Article
- Article
- Characterization of a novel VenusX orthogonal dual-layer multileaf collimator.Journal of applied clinical medical physics · 2024Article
- Evaluation of the dataset quality in gamma passing rate predictions using machine learning methods.The British journal of radiology · 2023Article
- Characterizing the interplay of treatment parameters and complexity and their impact on performance on an IROC IMRT phantom using machine learning.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2023Article
- Craniospinal Irradiation: A Dosimetric Comparison Between O-Ring Linac and Conventional C-arm Linac.Advances in radiation oncologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveHigh levels of beam modulation complexity (MC) and monitor units (MU) can compromise the plan deliverability of intensity-modulated radiotherapy treatments. Our study evaluates the effect of three treatment planning system (TPS) parameters on MC and MU using different multi-leaf collimator (MLC) architectures.
methods192 volumetric modulated arc therapy plans were calculated using one virtual prostate phantom considering three main settings: (1) three TPS-parameters (Convergence; Aperture Shape Controller, ASC; and Dose Calculation Resolution, DCR) selected from Eclipse v15.6, (2) four levels of dose-sparing priority for organs at risk (OAR), and (3) two treatment units with same nominal conformity resolution and different MLC architectures (Halcyon-v2 dual-layer MLC, DL-MLC & TrueBeam single-layer MLC, SL-MLC). We use seven complexity metrics to evaluate the MC, including two new metrics for DL-MLC, assessed by their correlation with γ passing rate (GPR) analysis.
resultsDL-MLC plans demonstrated lower dose-sparing values than SL-MLC plans (
conclusionsTPS-parameters selected do not change MC for DL-MLC architecture, but they might have a potential use to control the MU, PTV homogeneity or dose spillage for SL-MLC. Our new DL-MLC complexity metrics presented important information to be considered in future pre-treatment quality assurance programs. Finally, the prominent dependence between plan deliverability and priority applied to OAR dose sparing for DL-MLC needs to be analyzed and considered as an additional predictor of GPRs in further studies. ADVANCES IN KNOWLEDGE: Dose-sparing priority might influence in modulation complexity of DL-MLC.