Article in JMIR cardio, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03775161 (A First in Human Multi-center, Open Label, Prospective Study to Evaluate the Safety, Usability and Performance of the V-LAP™ System), which is not on this map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A First in Human Multi-center, Open Label, Prospective Study to Evaluate the Safety, Usability and Performance of the V-LAP™ System
Who cites it
4 citing papers in PubMed, 7 citations in OpenAlex.
- Percutaneous Strategies in Structural Heart Diseases: Focus on Chronic Heart Failure.Arquivos brasileiros de cardiologia · 2023Article
- A 3-Year Single Center Experience With Left Atrial Pressure Remote Monitoring: The Long and Winding Road.Frontiers in cardiovascular medicine · 2022Article
- Editorial: Advances and challenges in remote monitoring of patients with heart failure.Frontiers in cardiovascular medicine · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHeart failure (HF) management guided by the measurement of intracardiac and pulmonary pressure values obtained through innovative permanent intracardiac microsensors has been recently proposed as a valid strategy to individualize treatment and anticipate hemodynamic destabilization. These sensors have potential to reduce patient hospitalization rates and optimize quality of life.
objectiveThe aim of this study was to evaluate the usability and patients' attitudes toward a new permanent intracardiac device implanted to remotely monitor left intra-atrial pressures (V-LAP, Vectorious Medical Technologies, Tel Aviv, Israel) in patients with chronic HF.
methodsThe V-LAP system is a miniaturized sensor implanted percutaneously across the interatrial septum. The system communicates wirelessly with a "companion device" (a wearable belt) that is placed on the patient's chest at the time of acquisition/transmission of left heart pressure measurements. At first follow-up after implantation, the patients and health care providers were asked to fill out a questionnaire on the usability of the system, ease in performing the various required tasks (data acquisition and transmission), and overall satisfaction. Replies to the questions were mainly given using a 5-point Likert scale (1: very poor, 2: poor, 3: average, 4: good, 5: excellent). Further patient follow-ups were performed at 3, 6, and 12 months.
resultsUse and acceptance of the first 14 patients receiving the V-LAP technology worldwide and related health care providers have been analyzed to date. No periprocedural morbidity/mortality was observed. Before discharge, a tailored educational session was performed after device implantation with the patients and their health care providers. At the first follow-up, the mean score for overall comfort in technology use was 3.7 (SD 1.2) with 93% (13/14) of patients succeeding in applying and operating the system independently. For health care providers, the mean score for overall ease and comfort in use of the technology was 4.2 (SD 0.8). No significant differences were found between the patients' and health care providers' replies to the questionnaires. There was a general trend for higher scores in patients' usability reports at later follow-ups, in which the score related to overall comfort with using the technology increased from 3.0 (SD 1.4) to 4.0 (SD 0.7) (P=.40) and comfort with wearing and adjusting the measuring thoracic belt increased from 2.8 (SD 1.0) to 4.2 (SD 0.4) (P=.02).
conclusionsDespite the gravity of their HF pathology and the complexity of their comorbid profile, patients are comfortable in using the V-LAP technology and, in the majority of cases, they can correctly and consistently acquire and transmit hemodynamic data. Although the overall patient/care provider satisfaction with the V-LAP system seems to be acceptable, improvements can be achieved after ameliorating the design of the measuring tools.
trial registrationClincalTrials.gov NCT03775161; https://clinicaltrials.gov/ct2/show/NCT03775161.