Evidence map›Paper›PMID 33879201›Full record

ArticleRadiation oncology (London, England)2021

Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer.

Sunmin Park, Chai Hong Rim, Won Sup Yoon

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.3field-weighted citation impact, top 51% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Technology in cancer research & treatment
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 2 countries.

Sunmin ParkDepartment of Radiation Oncology, Ansan Hospital, Korea University, 123 Jeokgeum-ro, Danwon-gu, Ansan, Gyeonggi-do, 15355, Republic of Korea.
Chai Hong RimDepartment of Radiation Oncology, Ansan Hospital, Korea University, 123 Jeokgeum-ro, Danwon-gu, Ansan, Gyeonggi-do, 15355, Republic of Korea.
Won Sup YoonDepartment of Radiation Oncology, Ansan Hospital, Korea University, 123 Jeokgeum-ro, Danwon-gu, Ansan, Gyeonggi-do, 15355, Republic of Korea. irionyws@korea.ac.kr.ORCID http://orcid.org/0000-0002-6098-1993
Korea University · KR

Funding

Korea University (KR) K2010971
6 · The paper itself

Abstract

purposeBreast radiotherapy set-up is often uncertain. Actual dose distribution to normal tissues could be different from planned dose distribution. The objective of this study was to investigate such difference in dose distribution according to the extent of set-up error in breast radiotherapy. MATERIALS AND

methodsA total of 50 Gy with fraction size of 2 Gy was given to 30 left breasts with different set-ups applying a deep inspiration breath holding (DIBH) or a free breathing (FB) technique. Under the assumption that errors might come from translational axes of deep or caudal directions, the isocenter was shifted from the original tangential alignment every 2.5 mm to simulate uncertainty of deep and caudal tangential set-up in DIBH and FB. Changes were evaluated for dosimetric parameters for the heart, the left ventricle (LV), the left anterior descending coronary artery (LAD), and the ipsilateral lung.

resultsOn the original plan, mean doses of heart and ipsilateral lung were 2.0 ± 1.1 Gy and 3.7 ± 1.4 Gy in DIBH and 8.4 ± 1.3 Gy and 7.8 ± 1.5 Gy in FB, respectively. The change of dose distribution for the heart in DIBH was milder than that in FB. The deeper the tangential set-up, the worse the heart, LV, LAD, and ipsilateral lung doses, showing as much as 49.4%, 56.4%, 90.3%, and 26.1% shifts, respectively, in 5 mm DIBH setup. The caudal set-up did not show significant dose difference. In multiple comparison of DIBH, differences of mean dose occurred in all 7.5 mm deep set-ups for the heart (p = 0.025), the LV (p = 0.049), and LAD (p = 0.025) in DIBH.

conclusionsTo correct set-up error over indicated limitation for deep tangential set-up in DIBH at 5 mm action level, mean heart and ipsilateral lung doses are expected to increase approximately 50% and 25%, respectively.

Indexed as

Radiotherapy DosageAdultAgedBreast NeoplasmsBreath HoldingCoronary VesselsFemaleHeartHeart VentriclesHumansLungMiddle AgedOrgans at RiskRadiometryRadiotherapy Planning, Computer-AssistedReproducibility of ResultsBreast cancerDeep inspiration breath holdingHeartRadiotherapySet-up uncertainty

Identifiers

PMID33879201
PMCPMC8056628
OpenAlexW3125604739

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.