Evidence map›Paper›PMID 33873091›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2021

Optimizing trajectory ordering for fast radial ultra-short TE (UTE) acquisitions.

Xucheng Zhu, Fei Tan, Kevin Johnson, Peder Larson

Abstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Radial Hadamard-encodedMagma (New York, N.Y.) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Xucheng ZhuUC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States; Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States; GE Healthcare, Menlo Park, CA, United States.
Fei TanUC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States; Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States.
Kevin JohnsonMedical Physics, University of Wisconsin, Madison, WI, United States; Radiology, University of Wisconsin, Madison, WI, United States.
Peder LarsonUC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States; Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States. Electronic address: peder.larson@ucsf.edu.

Funding

MRI methods for high resolution imaging of the lungR01HL136965 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI JOHNSON, KEVIN MICHAEL, LARSON, PEDER ERIC ZUFALL · 2018 to 2021
$2.7M
NHLBI NIH HHS R01 HL136965
6 · The paper itself

Abstract

purposeAdditional spoiler gradients are required in 3D UTE sequences with random view ordering to suppress magnetization refocusing. By leveraging the encoding gradient induced spoiling effect, the spoiler gradients could potentially be reduced or removed to shorten the TR and increase encoding efficiency. An analysis framework is built that models the gradient spoiling effects and a new ordering scheme is proposed for fast 3D UTE acquisition. THEORY AND

methodsUTE signal evolution and spatial encoding gradient induced spoiling effect are derived from the Bloch equations. And the concept is validated in 2D radial UTE simulation. Then an optimized ordering scheme, named reordered 2D golden angle (r2DGA) scheme, for 3D UTE acquisition is proposed. The r2DGA scheme is compared to the sequential and 3D golden angle schemes in both phantom and volunteer studies.

resultsThe proposed r2DGA ordering scheme was applied to two applications, single breath-holding and free breathing 3D lung MRI. With r2DGA ordering scheme, breath-holding lung MRI scan increased 60% scan efficiency by removing the spoiler gradients and the free breathing scan reduced 20% scan time compared to the 3D golden angle scheme by reducing the spoiler gradients.

conclusionsThe proposed r2DGA ordering scheme UTE acquisition reduces the need of spoiler gradients and increases the encoding efficiency, and shows improvements in both breath-holding and free breathing lung MRI applications.

Indexed as

Magnetic Resonance ImagingRespirationComputer SimulationHumansImaging, Three-DimensionalLungPhantoms, ImagingLung MRINon-Cartesian MRIUTE

Identifiers

PMID33873091
PMCPMC8164474

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.