Evidence map›Paper›PMID 33871727›Full record

ReviewPediatric radiology2021

Magnetic resonance imaging in children with implants.

Camilo Jaimes, Diane Biaggotti, Gayathri Sreedher, Apeksha Chaturvedi, Michael M Moore, Amy R Danehy

Abstract readReview
PubMed Publisher
In one paragraph

Review in Pediatric radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. MRI safety-developing the right culture.Pediatric radiology · 2025
    Review
  2. Article
  3. Article
  4. Assessment of MRI Safety Practices in Saudi Arabia.Risk management and healthcare policy · 2023
    Article
  5. Intraoperative MR Imaging during Glioma Resection.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2022
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Camilo JaimesDivision of Neuroradiology, Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., 2nd floor, Main Building, Boston, MA, 02115, USA. camilo.jaimescobos@childrens.harvard.edu.ORCID http://orcid.org/0000-0002-7169-4244
Diane BiaggottiDepartment of Radiology, Boston Children's Hospital, Boston, MA, USA.
Gayathri SreedherPediatric Neuroradiology, Akron Children's Hospital, Akron, OH, USA.
Apeksha ChaturvediPediatric Radiology, University of Rochester Medical Center, University of Rochester, Rochester, NY, USA.
Michael M MoorePediatric Radiology, Milton S. Hershey Medical Center, Penn State University, Hershey, PA, USA.
Amy R DanehyDivision of Neuroradiology, Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., 2nd floor, Main Building, Boston, MA, 02115, USA.
Boston Children's Hospital · USAkron Children's Hospital · USPenn State Milton S. Hershey Medical Center · USUniversity of Rochester Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As access to MRI in pediatrics increases, the radiologist needs to become acquainted with the basic principles of MRI safety. As part of the image acquisition, the static magnetic field, gradient system, and the radiofrequency transmit-receive coil interact with medical and non-medical implants and can result in serious injury. The main stage of risk triage is based on the determination of whether the implant is MRI-safe, conditional, unsafe or unknown. Guiding principles include the strict adherence to manufacturer specifications for MRI-conditional implants and the assumption that an unknown implant is MR-unsafe. In this article we review considerations for common medical implants encountered in pediatrics including ventriculoperitoneal shunts, orthopedic hardware, orthodontic hardware, pacemakers, vascular stents, vagal nerve stimulators and cochlear implants. Finally, we review a set of high-yield considerations, including the non-communicative patient (sedated or non-verbal), susceptibility artifacts from unclear source, and the approach to an unknown implant.

Indexed as

ArtifactsMagnetic Resonance ImagingChildHumansRadio WavesStentsChildrenImplantsMagnetic resonance imagingSafety

Identifiers

PMID33871727
OpenAlexW3156119003

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked