Evidence map›Paper›PMID 33871699›Full record

ArticleHeart and vessels2021

Early and mid-term results of transcatheter aortic valve implantation and valve durability assessment.

Masato Tochii, Shintaro Nakano, Chiho Tokunaga, Toshihisa Asakura, Atsushi Iguchi, Hiroyuki Nakajima, Akihiro Yoshitake

Abstract read
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Masato TochiiDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Saitama, Hidaka, 350-1298, Japan. masatochii@yahoo.co.jp.ORCID http://orcid.org/0000-0002-1095-0275
Shintaro NakanoDepartment of Cardiology, Saitama Medical University International Medical Center, 1397-1 Yamane, Saitama, Hidaka, 350-1298, Japan.
Chiho TokunagaDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Saitama, Hidaka, 350-1298, Japan.
Toshihisa AsakuraDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Saitama, Hidaka, 350-1298, Japan.
Atsushi IguchiDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Saitama, Hidaka, 350-1298, Japan.
Hiroyuki NakajimaDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Saitama, Hidaka, 350-1298, Japan.
Akihiro YoshitakeDepartment of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Saitama, Hidaka, 350-1298, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to evaluate the early and mid-term outcomes of transcatheter aortic valve implantation (TAVI) and to assess valve durability. A total of 146 consecutive patients who underwent TAVI for severe aortic stenosis between October 2013 and August 2018 were retrospectively reviewed. All patients (mean age, 84 ± 6 years; age range 53-98 years; 42 males [28.7%]) had multiple comorbidities, with a mean logistic EuroSCORE of 30.9 ± 17.4%. Eighteen patients (12.3%) were aged 90 years or over. Five in-hospital deaths (3.4%) occurred, and 36 patients (24.7%) experienced major TAVI-related complications. With the transfemoral approach, 10 patients had major vascular complications, which mostly occurred with first-generation devices (n = 9) but less commonly with new-generation low-profile devices (P = 0.0078). During a follow-up period of 580 ± 450 (11-1738) days, 29 late deaths occurred. The survival rate was 86.0%, 78.0%, and 61.7% at 1, 2, and 3 years, respectively. Multivariate Cox hazard regression analysis revealed that more-than-moderate tricuspid regurgitation was the only independent risk factor for late deaths due to any cause (hazard ratio, 3.145; 95% confidence interval, 1.129-8.762; P = 0.0283). No statistically significant differences between post-TAVI before discharge from the hospital and at 4 years after TAVI were observed with respect to aortic valve area (1.76 ± 0.49 cm

Indexed as

Aortic Valve StenosisHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementAgedAged, 80 and overAortic ValveFemaleFluoroscopyHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeMid-term outcomeTAVIValve durability

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.