Evidence map›Paper›PMID 33869756›Full record

ArticleLaryngoscope investigative otolaryngology2021

Jet flow rate and needle position govern distal airway pressures during low-frequency jet ventilation.

Joshua Pertile, Bradford Smith, Michelle Mellenthin, Jennifer Wagner, Emily M DeBoer, Daniel S Fink

Open access · goldAbstract read
In one paragraph

Article in Laryngoscope investigative otolaryngology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Joshua PertileDepartment of Bioengineering University of Colorado Denver Anschutz Medical Campus Aurora Colorado USA.ORCID https://orcid.org/0000-0002-9343-4873
Bradford SmithDepartment of Bioengineering University of Colorado Denver Anschutz Medical Campus Aurora Colorado USA.ORCID https://orcid.org/0000-0002-1583-6762
Michelle MellenthinDepartment of Bioengineering University of Colorado Denver Anschutz Medical Campus Aurora Colorado USA.
Jennifer WagnerDepartment of Bioengineering University of Colorado Denver Anschutz Medical Campus Aurora Colorado USA.
Emily M DeBoerDepartment of Pediatrics, School of Medicine University of Colorado Aurora Colorado USA.
Daniel S FinkDepartment of Otolaryngology, School of Medicine University of Colorado Aurora Colorado USA.ORCID https://orcid.org/0000-0001-5162-2537
University of Colorado Anschutz Medical Campus · USColorado Mesa University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAlthough jet ventilation is frequently used during surgery for airway stenosis, little is known about distal airway pressures during jet ventilation. The objective of the study is to determine how jet pressure, flow rate, and position of the ventilation needle relate to distal airway pressure magnitude and homogeneity.

methodsTwo 3D models of the first five generations of the human airway tree were created. One is a duplicate of a human airway from a 15-year-old healthy male's computed tomography scan, and the other is an idealized symmetric model of human lung morphometry. Pressure transducers measured fifth-generation distal airway pressures in both models. A computer-controlled jet needle positioning system was used to ventilate the lung casts. The effects of jet needle position, jet pressure, and jet flow rate on distal airway pressure and homogeneity were measured.

resultsTotal entrained jet flow rate was the most reliable predictor of distal airway pressure. Pressure supplied to the jet ventilation needle had a positive linear relationship with distal airway pressure; however, this relationship was dependent on the jet needle flow resistance. As the ventilation needle moved closer to the tracheal wall, ventilation homogeneity decreased. Depth into the trachea was positively correlated with sensitivity of the needle to the tracheal wall.

conclusionIn this model, total entrained jet flow rate is a more robust predictor of distal airway pressure than jet inlet pressure. More homogeneous ventilation was observed in our model with the ventilation needle centered in the proximal region of the trachea.

Indexed as

flowhomogeneityjet ventilationpressure

Identifiers

PMID33869756
PMCPMC8035948
OpenAlexW3130986013

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked