Evidence map›Paper›PMID 33869745›Full record

ArticleIEEE robotics and automation letters2021

An Active Steering Hand-held Robotic System for Minimally Invasive Orthopaedic Surgery Using a Continuum Manipulator.

Justin H Ma, Shahriar Sefati, Russell H Taylor, Mehran Armand

Open access · greenAbstract read
In one paragraph

Article in IEEE robotics and automation letters, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 46 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review of Enhanced Handheld Surgical Drills.Critical reviews in biomedical engineering · 2023
    Review
  7. Towards Reducing Visual Workload in Surgical Navigation: Proof-of-concept of an Augmented Reality Haptic Guidance System.Computer methods in biomechanics and biomedical engineering. Imaging & visualization · 2023
    Article
  8. Data-driven Shape Sensing of Continuum Dexterous Manipulators Using Embedded Capacitive Sensor.Proceedings of IEEE Sensors. IEEE International Conference on Sensors · 2023
    Article
  9. Tsetse fly inspired steerable bone drill-a proof of concept.Frontiers in bioengineering and biotechnology · 2023
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Justin H MaLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Shahriar SefatiLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Russell H TaylorLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Mehran ArmandLaboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA.
Johns Hopkins University · US

Funding

Image-Guided Workstation and Tools for the Treatment of Bone DefectsR01EB016703 · NIBIB · UNIVERSITY OF ARKANSAS AT FAYETTEVILLE · PI ARMAND, MEHRAN · 2013 to 2022
$3.4M
Robotic System for Spinal Decompression and Interbody FusionR01AR080315 · NIAMS · UNIVERSITY OF ARKANSAS AT FAYETTEVILLE · PI ARMAND, MEHRAN, JAIN, AMIT · 2022 to 2025
$1.7M
NIAMS NIH HHS R01 AR080315NIBIB NIH HHS R01 EB016703
6 · The paper itself

Abstract

This paper presents the development and experimental evaluation of an active steering hand-held robotic system for milling and curved drilling in minimally invasive orthopaedic interventions. The system comprises a cable-driven continuum dexterous manipulator (CDM), an actuation unit with a handpiece, and a flexible, rotary cutting tool. Compared to conventional rigid drills, the proposed system enhances dexterity and reach in confined spaces in surgery, while providing direct control to the surgeon with sufficient stability while cutting/milling hard tissue. Of note, for cases that require precise motion, the system is able to be mounted on a positioning robot for additional controllability. A proportional-derivative (PD) controller for regulating drive cable tension is proposed for the stable steering of the CDM during cutting operations. The robotic system is characterized and tested with various tool rotational speeds and cable tensions, demonstrating successful cutting of three-dimensional and curvilinear tool paths in simulated cancellous bone and bone phantom. Material removal rates (MRRs) of up to 571 mm

Indexed as

Compliant Joints and MechanismsMedical Robots and Systems

Identifiers

PMID33869745
PMCPMC8052093
OpenAlexW3131831054

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.