Evidence map›Paper›PMID 33869707›Full record

ArticlePractical laboratory medicine2021

High-throughput nuclear magnetic resonance measurement of citrate in serum and plasma in the clinical laboratory.

Erwin Garcia, Margery A Connelly, Steven P Matyus, James D Otvos, Irina Shalaurova

Open access · goldAbstract read
In one paragraph

Article in Practical laboratory medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Erwin GarciaLaboratory Corporation of America Holdings (Labcorp), Morrisville, NC, USA.
Margery A ConnellyLaboratory Corporation of America Holdings (Labcorp), Morrisville, NC, USA.
Steven P MatyusLaboratory Corporation of America Holdings (Labcorp), Morrisville, NC, USA.
James D OtvosLaboratory Corporation of America Holdings (Labcorp), Morrisville, NC, USA.
Irina ShalaurovaLaboratory Corporation of America Holdings (Labcorp), Morrisville, NC, USA.
LabCorp (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesDespite reports highlighting citrate association with different diseases, serum citrate is scarcely used for diagnosis. Existing methods to quantify citrate are limited by their complexity and practicality of implementation. A simple and rapid NMR-based method to measure circulating citrate is described here, and its analytical performance evaluated.

designand Methods: Citrate was quantified from NMR spectra using a non-negative linear least squares deconvolution algorithm. The analytical characteristics of the assay were evaluated using CLSI guidelines. To determine if the assay has adequate sensitivity to measure clinically relevant concentrations of citrate, the assay was used to quantify citrate in apparently healthy adults (n ​= ​553), and in the general population (n ​= ​133,576).

resultsThe LOQ for the assay was determined to be 1.48 ​mg/dL. Linearity was demonstrated over a wide range of concentrations (1.40-4.46 ​mg/dL). Coefficients of variation (%CV) for intra- and inter-assay precision ranged from 5.8-9.3 and 5.2-9.6%, respectively. Substances tested did not elicit interference with assay results. Specimen type comparison revealed <1% bias between serum and plasma samples, except for heparin plasma (3% bias). Stability was demonstrated up to 8 days at room temperature and longer at lower temperatures. In a cohort of apparently healthy adults, the reference interval was <1.48-2.97 ​mg/dL. Slightly higher values were observed in the general population.

conclusionsThe newly developed NMR-based assay exhibits analytical characteristics that allow the accurate quantification of clinically relevant citrate concentrations. The assay provides a simple and fast means to analyze samples for research and clinical studies.

Indexed as

1D, one dimensional1H, protonCitrateCLSI, Clinical and Laboratory Standards InstituteCV, coefficient of variationLOB, limit of blankLOD, limit of detectionLOQ, limit of quantitationMortalityMS, Mass SpectrometryNAFLD, non-alcoholic fatty liver diseaseNMR, Nuclear magnetic resonance spectroscopyNuclear magnetic resonance spectroscopy

Identifiers

PMID33869707
PMCPMC8042410
OpenAlexW3138926689

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.