Evidence map›Paper›PMID 33867263›Full record

ArticleClinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology2021

Biophysical characterization of local field potential recordings from directional deep brain stimulation electrodes.

M Sohail Noor, Cameron C McIntyre

Abstract read
In one paragraph

Article in Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Localizing beta synchronous neurons in the STN using directional DBS recordings and patient-specific biophysical models.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2026
    Article
  2. Article
  3. A survey on integral equations for bioelectric modeling.Physics in medicine and biology · 2024
    Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

M Sohail NoorDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
Cameron C McIntyreDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA. Electronic address: ccm4@case.edu.

Funding

CRCNS: Patient-Specfic Models of Local Field Potentials in Subcallosal CingulateR01MH106173 · NIMH · CASE WESTERN RESERVE UNIVERSITY · PI MCINTYRE, CAMERON · 2014 to 2019
$2.0M
Biophysical Characterization of Subthalamic Local Field Potentials in Parkinson's DiseaseR01NS119520 · NINDS · DUKE UNIVERSITY · PI MCINTYRE, CAMERON · 2021 to 2024
$1.9M
NIMH NIH HHS R01 MH106173NINDS NIH HHS R01 NS119520
6 · The paper itself

Abstract

objectiveTwo major advances in clinical deep brain stimulation (DBS) technology have been the introduction of local field potential (LFP) recording capabilities, and the deployment of directional DBS electrodes. However, these two technologies are not operationally integrated within current clinical DBS devices. Therefore, we evaluated the theoretical advantages of using directional DBS electrodes for LFP recordings, with a focus on measuring beta-band activity in the subthalamic nucleus (STN).

methodsWe used a computational model of human STN neural activity to simulate LFP recordings. The model consisted of 235,280 anatomically and electrically detailed STN neurons surrounding the DBS electrode, which was previously optimized to mimic beta-band synchrony in the dorsolateral STN. We then used that model system to compare LFP recordings from cylindrical and directional DBS contacts, and evaluate how the selection of different contacts for bipolar recording affected the LFP measurements.

resultsThe model predicted two advantages of directional DBS electrodes over cylindrical DBS electrodes for STN LFP recording. First, recording from directional contacts could provide additional insight on the location of a synchronous volume of neurons within the STN. Second, directional contacts could detect a smaller volume of synchronous neurons than cylindrical contacts, which our simulations predicted to be a ~0.5 mm minimum radius.

conclusionsSTN LFP recordings from 8-contact directional DBS electrodes (28 possible bipolar pairs) can provide more information than 4-contact cylindrical DBS electrodes (6 possible bipolar pairs), but they also introduce additional complexity in analyzing the signals. SIGNIFICANCE: Integration of directional electrodes with DBS systems that are capable of LFP recordings could improve localization of targeted volumes of synchronous neurons in PD patients.

Indexed as

Deep Brain StimulationElectrodes, ImplantedHumansModels, NeurologicalParkinson DiseaseSubthalamic NucleusBetaNeuronOscillationParkinson’s diseaseSubthalamic nucleusSynchrony

Identifiers

PMID33867263
PMCPMC8137656

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.