ArticleInternational orthopaedics2021
Comparison of different fixation techniques for periprosthetic fractures: a biomechanical study of a new implant.
Article in International orthopaedics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2026Article
- The Relationship Between Arthroplasty Surgeons' Experience Level and Optimal Cable Tensioning in the Fixation of Extended Trochanteric Osteotomy.Geriatric orthopaedic surgery & rehabilitation · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe ideal treatment method for periprosthetic fractures is controversial due to the risks of current methods. Single-cortex screw fixation in prosthesis may lead to implant failure. Therefore, we aimed to develop an implant that lowers the risk for complications. For this study, we designed and tested two new implant models. The first model was a plate with a combination of U nails and cerclage holes. The second model was a U nail plate with a screw, which combines a plate screw with U nail (staples). Our study aimed to compare the stability of two newly designed implants with classical treatment modalities. We used 27 (in 3 groups) artificial bone models and 9 different test models.
methodsThe ISO 7206-4:2010 (E) standards were used for 27 bones in nine groups tested under laboratory conditions. In our study, we examined nine different groups. In group 1, hip the prosthesis was extracted, and a revision femoral stem was embedded. In group 2, periprosthetic fractures were repaired with a plate and cable. In group 3, periprosthetic fractures were repaired with a plate and stapler. In group 4, periprosthetic fractures were repaired with a plate and stapler cable. In group 5, periprosthetic fractures were repaired with a plate stapler and screw. Groups 6 and 7 were the control groups. Group 6 was the only artificial bone group, and group 7 was the prosthesis embedded bone group. Group 8 was periprosthetic fractures treated with unicortical screw fixation with cerclage, and group 9 was periprosthetic fractures treated with unicortical screw fixation. Axial loading was applied to the bones. The yield strength of the system was determined by loading the synthetic bone models with a constant compression speed of 5 mm/min through the centre of motion using the Geratech SH 2000 testing system. During the tests, load and displacement values were recorded, and the stiffness of the models was calculated based on those values.
resultsAccording to our results, the greatest durability was found in the revision hip prosthesis group (1511 N), and the weakest performance was found in the plate with the stapler implant group (163N). When comparing the data of groups according to compression, significant differences were found in group 2 with groups 1, 4, 5, and 7; group 3 with group 1; group 8 with groups 1 and 5; and group 9 with 1, 5, 7, and according to breakage, significant differences were found in group2 with groups 1, 3, 5, and 7; group 3 with group 1; group 8 with groups 1 and 5; and group 9 with groups 1, 5, and 7 (p<0.001). DISCUSSION: The revision hip prosthesis treatment for periprosthetic fractures showed the best performance, followed by the plate with stapler screw. In older patients, U nail-augmented implants may be a good alternative for periprosthetic fractures. Unicortical screw and cerclage wire combination fixation results were unsatisfactory results in this study.
conclusionThis is an experimental study, so further studies, especially patient-specific studies, should be made to expand the findings of this study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.