Evidence map›Paper›PMID 33865360›Full record

Observational studyBMC musculoskeletal disorders2021

Intra- and inter-observer reliability of implant positioning evaluation on a CT-based three-dimensional postoperative matching system for total knee arthroplasty.

Shotaro Watanabe, Ryuichiro Akagi, Yuki Shiko, Yoshimasa Ono, Yohei Kawasaki, Toshihiro Ohdera, Seiji Ohtori, Takahisa Sasho

Abstract readObservational Study
In one paragraph

Observational study in BMC musculoskeletal disorders, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shotaro WatanabeDepartment of Orthopaedic Surgery, Graduate School of Medicine, Development of Orthopaedic Surgery, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Japan.
Ryuichiro AkagiDepartment of Orthopaedic Surgery, Graduate School of Medicine, Development of Orthopaedic Surgery, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Japan. rakagi@chiba-u.jp.
Yuki ShikoBiostatistics Section, Clinical Research Center, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba, Japan.
Yoshimasa OnoDepartment of Orthopaedic Surgery, Graduate School of Medicine, Development of Orthopaedic Surgery, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Japan.
Yohei KawasakiBiostatistics Section, Clinical Research Center, Chiba University Hospital, 1-8-1 Inohana, Chuo-ku, Chiba, Japan.
Toshihiro OhderaFukuoka Orthopaedic Hospital, 2-10-50 Yanagouchi, Minami-ward, Fukuoka-city, Fukuoka, Japan.
Seiji OhtoriDepartment of Orthopaedic Surgery, Graduate School of Medicine, Development of Orthopaedic Surgery, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Japan.
Takahisa SashoDepartment of Orthopaedic Surgery, Graduate School of Medicine, Development of Orthopaedic Surgery, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe evaluation of postoperative total knee arthroplasty (TKA) alignment mainly relies on measurement data obtained from plain radiographs. The aim of this retrospective observational study was to document the intra- and inter-observer reliability in assessment of TKA component positioning after surgery using a three-dimensional (3D) computed tomography (CT) image matching system.

methodsFourteen knees from 14 patients who received primary TKA were included, and images were analyzed by blinded readers not associated with the surgeries. The examiner digitized the reference points according to defined landmarks, and the designated size component was superimposed to the 3D reconstructed CT model for measurement. In addition to the evaluation of implant position against the coronal and sagittal lower limb mechanical axes that were defined based on bony landmarks, implant position against axes connecting implant-based reference points that are easier to indicate was evaluated.

resultsThe overall intra- and inter-observer reliabilities determined by the intraclass correlation coefficients (ICC) of the implant alignment measurement for both femoral and tibial components were good (ICC > 0.60), except in the direction of femoral flexion and extension, for both mechanical and implant-based axes. The difference between implant alignment measurements according to the traditional mechanical axis and the implant-based axis ranged between means of 0.08

conclusionsThe postoperative evaluation of implant position in the coronal and sagittal planes using 3D-CT image matching is reliable and has good reproducibility except for the sagittal alignment assessment of the femoral component. The measured implant position according to the traditional mechanical axis and the implant-based axis were slightly but significantly different.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisFemurHumansImaging, Three-DimensionalKnee JointReproducibility of ResultsTibiaTomography, X-Ray Computed3D-CTImplant positionInter‐observer reliabilityIntra‐observer reliabilityPostoperative evaluationTotal knee arthroplasty

Identifiers

PMID33865360
PMCPMC8053298

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.