Evidence map›Paper›PMID 33861228›Full record

ArticleLab on a chip2021

Measuring barrier function in organ-on-chips with cleanroom-free integration of multiplexable electrodes.

Elsbeth G B M Bossink, Mariia Zakharova, Douwe S de Bruijn, Mathieu Odijk, Loes I Segerink

Open access · hybridAbstract read
In one paragraph

Article in Lab on a chip, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 39 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Mechano-Organ-on-Chip for Cancer Research.International journal of molecular sciences · 2026
    Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Review
  14. Article
  15. Article
  16. Review
  17. Review
  18. Review
  19. Article
  20. Integrating mechanical sensor readouts into organ-on-a-chip platforms.Frontiers in bioengineering and biotechnology · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 3 countries.

Elsbeth G B M BossinkBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical Medical Center and Max Planck Institute for Complex Fluid Dynamics, University of Twente, The Netherlands. e.g.b.m.bossink@utwente.nl m.zakharova@utwente.nl.ORCID 0000-0002-4832-6144
Mariia ZakharovaBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical Medical Center and Max Planck Institute for Complex Fluid Dynamics, University of Twente, The Netherlands. e.g.b.m.bossink@utwente.nl m.zakharova@utwente.nl.ORCID 0000-0003-0206-0966
Douwe S de BruijnBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical Medical Center and Max Planck Institute for Complex Fluid Dynamics, University of Twente, The Netherlands. e.g.b.m.bossink@utwente.nl m.zakharova@utwente.nl.ORCID 0000-0002-9547-3411
Mathieu OdijkBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical Medical Center and Max Planck Institute for Complex Fluid Dynamics, University of Twente, The Netherlands. e.g.b.m.bossink@utwente.nl m.zakharova@utwente.nl.ORCID 0000-0002-4467-9604
Loes I SegerinkBIOS Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical Medical Center and Max Planck Institute for Complex Fluid Dynamics, University of Twente, The Netherlands. e.g.b.m.bossink@utwente.nl m.zakharova@utwente.nl.ORCID 0000-0001-6943-8156
Max Planck University of Twente Center for Complex Fluid Dynamics · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Transepithelial/transendothelial electrical resistance (TEER) measurements can be applied in organ-on-chips (OoCs) to estimate the barrier properties of a tissue or cell layer in a continuous, non-invasive, and label-free manner. Assessing the barrier integrity in in vitro models is valuable for studying and developing barrier targeting drugs. Several systems for measuring the TEER have been shown, but each of them having their own drawbacks. This article presents a cleanroom-free fabrication method for the integration of platinum electrodes in a polydimethylsiloxane OoC, allowing the real-time assessment of the barrier function by employing impedance spectroscopy. The proposed method and electrode arrangement allow visual inspection of the cells cultured in the device at the site of the electrodes, and multiplexing of both the electrodes in one OoC and the number of OoCs in one device. The effectiveness of our system is demonstrated by lining the OoC with intestinal epithelial cells, creating a gut-on-chip, where we monitored the formation, as well as the disruption and recovery of the cell barrier during a 21 day culture period. The application is further expanded by creating a blood-brain-barrier, to show that the proposed fabrication method can be applied to monitor the barrier formation in the OoC for different types of biological barriers.

Indexed as

Dielectric SpectroscopyLab-On-A-Chip DevicesElectric ImpedanceElectrodesEpithelial Cells

Identifiers

PMID33861228
PMCPMC8130670
OpenAlexW3153876691

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.