Evidence map›Paper›PMID 33861155›Full record

ArticleThe British journal of radiology2021

Diagnostic efficacy of joint ultrasonography, dual-energy computed tomography and minimally invasive arthroscopy on knee gouty arthritis, a comparative study.

Yuesheng Xie, Ling Li, Riqiang Luo, Ting Xu, Lin Yang, Fangping Xu, Haobo Lin, Guangfeng Zhang, Xiao Zhang

Open access · greenAbstract readComparative Study
In one paragraph

Article in The British journal of radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Ultrasound Features in Gout: An Overview.Medical sciences (Basel, Switzerland) · 2024
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Yuesheng XieThe Second School of Clinical Medicine, Southern Medical University, Guangzhou, China.
Ling LiDepartment of Rheumatology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
Riqiang LuoDepartment of Rheumatology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
Ting XuDepartment of Rheumatology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
Lin YangDepartment of Radiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
Fangping XuDepartment of Pathology and Laboratory Medicine, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
Haobo LinDepartment of Rheumatology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
Guangfeng ZhangDepartment of Rheumatology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China.
Xiao ZhangThe Second School of Clinical Medicine, Southern Medical University, Guangzhou, China.
Guangdong Academy of Medical Sciences · CNGuangdong Provincial People's Hospital · CNSouthern Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to investigate the diagnostic performance of minimally invasive arthroscopy for knee gout when comparing with joint ultrasonography and dual-energy computed tomography (DECT).

methodsFrom January 2016 to December 2018, 121 inpatients with knee joint swelling and pain were prospectively enrolled, including 63 gout patients and 58 non-gout patients. All patients underwent pre-operative ultrasonography and DECT to evaluate knee joint monosodium urate (MSU) deposits, followed by minimally invasive arthroscopy. The gold-standard for gout diagnosis was defined as the detection of MSU crystals in the synovial fluid under polarizing microscopic or pathological analysis.

resultsThe diagnostic results of ultrasonic double contour sign, hyperechogenic foci, MSU deposition (detected by DECT), MSU deposition (detected by arthroscopy) and MSU deposition in cartilage (detected by arthroscopy) were significantly associated with that of the gold-standard. Except for hyperechogenic foci, the other four indexes had high sensitivity and specificity (approximately or over 80%) and a large odds ratio (OR) (14.73 to 36.56), indicating good diagnostic performance. Detection of MSU deposition in cartilage by arthroscopy had a good diagnostic agreement with the ultrasonic double contour sign (κ = 0.711,

conclusionJoint ultrasonography, DECT, and minimally invasive arthroscopy had high sensitivity and specificity for the diagnosis of knee gouty arthritis. Minimally invasive arthroscopy was superior to joint ultrasonography and DECT, which can be a useful supplement for the diagnosis of gout. ADVANCES IN KNOWLEDGE: This is the first study comparing the diagnostic performance for knee gout among the joint ultrasonography, DECT, and minimally invasive arthroscopy.

Indexed as

Arthritis, GoutyArthroscopyFemaleHumansKnee JointMaleMiddle AgedOdds RatioProspective StudiesSensitivity and SpecificitySynovial FluidTomography, X-Ray ComputedUltrasonographyUric AcidUric Acid

Identifiers

PMID33861155
PMCPMC8506185
OpenAlexW3153935127

What OpenQuestion holds

Textmetadata
Read underepoch 390