Evidence map›Paper›PMID 33858517›Full record

ArticleInternational journal of retina and vitreous2021

Versatility of use of fibrin glue in wound closure and vitreo-retinal surgery.

Gabriela Lopezcarasa-Hernandez, Jose-Francisco Perez-Vazquez, Jose-Luis Guerrero-Naranjo, Maria A Martinez-Castellanos

Open access · goldAbstract read
In one paragraph

Article in International journal of retina and vitreous, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Gabriela Lopezcarasa-HernandezRetina and Vitreus Department, Asociacion para Evitar la Ceguera en México, IAP, Vicente García Torres 46, Col. Barrio San Lucas, Coyoacan, 04030, Mexico City, Mexico. gabylcarasa@me.com.ORCID http://orcid.org/0000-0003-4515-2449
Jose-Francisco Perez-VazquezRetina and Vitreus Department, Asociacion para Evitar la Ceguera en México, IAP, Vicente García Torres 46, Col. Barrio San Lucas, Coyoacan, 04030, Mexico City, Mexico.
Jose-Luis Guerrero-NaranjoRetina and Vitreus Department, Asociacion para Evitar la Ceguera en México, IAP, Vicente García Torres 46, Col. Barrio San Lucas, Coyoacan, 04030, Mexico City, Mexico.
Maria A Martinez-CastellanosRetina and Vitreus Department, Asociacion para Evitar la Ceguera en México, IAP, Vicente García Torres 46, Col. Barrio San Lucas, Coyoacan, 04030, Mexico City, Mexico.
Asociacion Para Evitar la Ceguera en México Hospital Dr. Luis Sánchez Bulnes · MXHospital Angeles Pedregal · MX

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFibrin glue is an absorbable blood-derived product, a biological tissue adhesive which imitates the final stages of the coagulation cascade, it produces a firm clot, forming a seal along the whole length of the wound, the resultant fibrin clot degrades physiologically into granulation tissue 2 weeks after the application. Biological glue has been used extensively in many forms of surgical procedures. Its use in eye surgery has grown lately as we have evidence that showed it was effective in securing conjunctival grafts in pterygium surgery, in securing wounds after glaucoma surgery and more importantly in 20G and 23G vitrectomy. PURPOSE: The aim of this study is to present our experience in the use of fibrin glue in vitreoretinal surgery. MATERIAL AND

methodsWe included 281 eyes of 221 patients who underwent vitreoretinal surgery during the period of May 2009 to July 2012, the preoperative diagnoses were as following: proliferative diabetic retinopathy, rhegmatogenous retinal detachment, macular hole, epiretinal membrane, luxation of cataratous nucleous and cortex, intraocular lens luxation, penetrating trauma, silicone extraction, phaco + IOL + vitrectomy + Ahmed valve implant, vitreous biopsy and optic nerve pit associated to macular detachment. The procedures were performed with Alcon Accurus Surgical System 20-gauge, 23-gauge or a combination of both. We used fibrin glue in all of the 20-gauge sclerotomies and leaking 23-gauge sclerotomies, scleral wound for IOL extraction, conjunctival peritomy for buckle implantation, conjunctiva in Ahmed valve implant, corneal graft in corneal perforation in trauma and leaking corneal wounds for phacoemulsification, in an optic pit, and in subretinal space in a giant retinal tear.

resultsWe did not use any suture in any of the patients throughout the different procedures, there was no leakage in any wounds in the postoperative period, we found no inflammatory reaction, infection, and whenever we had excess amount, it was trimmed. Two patients presented a small dehiscence of the wound that was corrected in-office with a small amount of fibrin glue in the post-operative period.

conclusionsFibrin glue reduces surgical time, it is a good sealant, safe, with minimal allergic or toxic reactions and inflammation, minimizes bleeding, easy to undo and that eventually degrades. This small series shows that fibrin glue is a viable alternative for tissue coaptation in vitreoretinal surgery. However, further studies are required before fibrin glue takes the place of sutures.

Indexed as

Fibrin glueRetinal detachment surgeryRhegmatogenous retinal detachmentVitreoretinal surgery

Identifiers

PMID33858517
PMCPMC8050906
OpenAlexW3155415661

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.