Evidence map›Paper›PMID 33857473›Full record

ArticleJournal of immunological methods2021

Quantification of trivalent non-replicating rotavirus vaccine antigens in the presence of aluminum adjuvant.

David McAdams, Kyle Lakatos, Marcus Estrada, Dexiang Chen, Brian Plikaytis, Robert Sitrin, Jessica A White

Open access · hybridAbstract read
In one paragraph

Article in Journal of immunological methods, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

David McAdamsMedical Devices and Health Technologies Global Program, Formulation Technologies, PATH, Seattle, WA, USA.
Kyle LakatosMedical Devices and Health Technologies Global Program, Formulation Technologies, PATH, Seattle, WA, USA.
Marcus EstradaMedical Devices and Health Technologies Global Program, Formulation Technologies, PATH, Seattle, WA, USA.
Dexiang ChenMedical Devices and Health Technologies Global Program, Formulation Technologies, PATH, Seattle, WA, USA.
Brian PlikaytisBiostat Consulting LLC, Big Canoe, GA, USA.
Robert SitrinThe Center for Vaccine Innovation and Access, PATH, Washington, DC, USA.
Jessica A WhiteMedical Devices and Health Technologies Global Program, Formulation Technologies, PATH, Seattle, WA, USA. Electronic address: jawhite@path.org.
Program for Appropriate Technology in Health · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Parenterally administered rotavirus vaccines may overcome the low efficacy observed in resource-poor regions that use live oral formulations. We have reported work on a trivalent nonreplicating rotavirus vaccine (NRRV) for parenteral administration consisting of the recombinant tetanus toxoid P2 CD4 epitope fused to a truncated VP8* fragment (P2-VP8*) for the P[4], P[6], and P[8] serotypes of rotavirus adjuvanted with aluminum. An essential part of developing this vaccine candidate was devising quantification methods for each antigen in the trivalent NRRV in the presence of aluminum adjuvant. This report describes the development of quantitative inhibition enzyme-linked immunosorbent assays (ELISAs) for in vitro antigenicity determination of the adjuvanted trivalent NRRV using serotype-specific monoclonal antibodies (mAbs) against each of the P2-VP8* antigens. Adjuvanted trivalent vaccine samples are titrated and incubated with a constant concentration of specific mAbs against each NRRV P2-VP8* antigen variant. Unbound mAbs are measured by ELISA to indirectly quantify the amount of each antigen present in the trivalent vaccine. Sensitive, specific, and reproducible inhibition ELISAs were developed and qualified for each antigen and used for final product quantification and release testing without desorption of the vaccine antigen.

Indexed as

Adjuvants, ImmunologicAntibodies, MonoclonalEnzyme-Linked Immunosorbent AssayEpitopes, T-LymphocyteHumansImmunogenicity, VaccineInfusions, ParenteralPeptidesRecombinant Fusion ProteinsRNA-Binding ProteinsRotavirus VaccinesTetanus ToxoidViral Nonstructural ProteinsAdjuvants, ImmunologicAntibodies, MonoclonalEpitopes, T-LymphocyteNS35 protein, rotavirusPeptidesRecombinant Fusion ProteinsRNA-Binding ProteinsRotavirus VaccinesTetanus ToxoidViral Nonstructural ProteinsNonreplicating rotavirus vaccineNRRVRotavirus

Identifiers

PMID33857473
PMCPMC8208242
OpenAlexW3154965033

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.