Evidence map›Paper›PMID 33857011›Full record

Trial reportJournal of medical Internet research2021

Validation of the Withings ScanWatch as a Wrist-Worn Reflective Pulse Oximeter: Prospective Interventional Clinical Study.

Romain Kirszenblat, Paul Edouard

Registry-linked trialOpen access · goldAbstract readClinical TrialValidation Study
In one paragraph

Trial report in Journal of medical Internet research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04380389 (Accuracy of ScanWatch Pulse Oximeter With Profound Hypoxia), which is not on this map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
3.3field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04380389 nacompletednot on this map

Accuracy of ScanWatch Pulse Oximeter With Profound Hypoxia

TypeinterventionalSponsorWithingsRan2020 to 2020Enrolled14ConditionsOximetryArmshypoxia
3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 48 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Performance of a commercial smart watch compared to polysomnography reference for overnight continuous oximetry measurement and sleep apnea evaluation.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2024
    Article
  7. The impact of study type and sleep measurement on oxygen desaturation index calculation.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2024
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Romain Kirszenblat *Withings, Issy-Les-Moulineaux, France.ORCID 0000-0002-8967-1614
Paul Edouard *Withings, Issy-Les-Moulineaux, France.ORCID 0000-0002-7558-1036

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA decrease in the level of pulse oxygen saturation as measured by pulse oximetry (SpO

objectiveThe main objective of this monocentric and prospective clinical study with single-blind analysis was to test and validate the accuracy of the reflective pulse oximeter function of the Withings ScanWatch to measure SpO

methodsTo achieve these objectives, we included 14 healthy participants aged 23-39 years in the study, and we induced several stable plateaus of arterial oxygen saturation (SaO

resultsAfter removal of the inconclusive measurements, we obtained 275 and 244 conclusive measurements with the two ScanWatches on the participants' right and left wrists, respectively, evenly distributed among the 3 predetermined SpO

conclusionsIn conclusion, the Withings ScanWatch is able to measure SpO

trial registrationClinicalTrials.gov NCT04380389; http://clinicaltrials.gov/ct2/show/NCT04380389.

Indexed as

HypoxiaOximetryAdultCOVID-19FemaleHealthy VolunteersHumansLung DiseasesMaleMonitoring, PhysiologicOxygenProspective StudiesSingle-Blind MethodWristYoung AdultOxygenaccuracyconnected watchCOPDCOVID-19neural networkoximeteroxygenpulse oxygen saturationreflective pulse oximeterrespiratoryrespiratory diseasesafetysleep apnea syndromeSpO2validationwearableWithings ScanWatch

Identifiers

PMID33857011
PMCPMC8078374
OpenAlexW3153447744

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.