Evidence map›Paper›PMID 33856566›Full record

ArticleThe ultrasound journal2021

Intra- and inter-rater reliability of rectus femoris muscle thickness measured using ultrasonography in healthy individuals.

Yosuke Takahashi, Yuji Fujino, Kohei Miura, Ayumi Toida, Tadamitsu Matsuda, Shigeru Makita

Open access · goldAbstract read
In one paragraph

Article in The ultrasound journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Yosuke TakahashiDepartment of Rehabilitation Center, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, 350-1298, Japan.
Yuji FujinoDepartment of Physical Therapy, Faculty of Health Science, Juntendo University, 3-2-12, Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan. y.fujino.pb@juntendo.ac.jp.
Kohei MiuraDepartment of Rehabilitation Center, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, 350-1298, Japan.
Ayumi ToidaDepartment of Central Examination, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, 350-1298, Japan.
Tadamitsu MatsudaDepartment of Physical Therapy, Faculty of Health Science, Juntendo University, 3-2-12, Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan.
Shigeru MakitaDepartment of Cardiac Rehabilitation, Saitama Medical University International Medical Center, Hidaka, Saitama, 1397-1 Yamane350-1298, Japan.
Saitama Medical University · JPJuntendo University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUltrasonography (US) is a feasible and accessible method for the measurement of skeletal muscle mass. This technique presents acceptable intra-rater reliability; however, there are a few reports on its inter-rater reliability. Additionally, relative reliability should equally be inspected to determine the presence of systematic errors. Therefore, this study aimed to investigate the intra- and inter-rater reliabilities and absolute reliability of rectus femoris muscle thickness as measured using US.

methodsThe participants included in our study comprised 12 healthy young men (26.5 ± 3.9 years. Rectus femoris muscle thickness was measured from the right side of the thigh using US by two trained physical therapists. Inter- and intra-rater reliabilities were determined using the intraclass correlation coefficient (ICC) (1, 1) and ICC (2, 1) methods, respectively. Absolute reliability was evaluated using Bland - Altman analysis. Additionally, we calculated the minimal detectable change at the 95% level of confidence (MDC

resultAccording to the results of the Bland - Altman analysis, no fixed or proportional errors were present. The ICC (1, 1) was 0.95, and the ICC (2, 1) was 0.70. The MDC

conclusionsIn our study, intra- and inter-rater reliabilities were measured at "excellent" and "moderate" levels in the healthy individuals based on a previously defined scale. Moreover, we determined the measurement error for quantifying rectus femoris thickness. Therefore, the measurement of rectus femoris thickness using US could be considered applicable in clinical research.

Indexed as

Rectus femoris muscleReliabilitySkeletal muscle massUltrasonography

Identifiers

PMID33856566
PMCPMC8050162
OpenAlexW3156937883

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.