Evidence map›Paper›PMID 33856524›Full record

ArticleEuropean radiology2021

Investigating new CT contrast agents: a phantom study exploring quantification and differentiation methods for high-Z elements using dual-energy CT.

Todd C Soesbe, Yin Xi, Khaled Nasr, John R Leyendecker, Robert E Lenkinski, Matthew A Lewis

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.4field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Tantalum-Based Nanomaterials: From Properties to Biomedical Applications.Advanced materials (Deerfield Beach, Fla.) · 2026
    Review
  3. Review
  4. Human serum albumin-based KBiFJournal of nanobiotechnology · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Todd C SoesbeDepartment of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390-9061, USA. todd.soesbe@utsouthwestern.edu.ORCID http://orcid.org/0000-0002-6129-5549
Yin XiDepartment of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390-9061, USA.
Khaled NasrDepartment of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390-9061, USA.
John R LeyendeckerDepartment of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390-9061, USA.
Robert E LenkinskiDepartment of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390-9061, USA.
Matthew A LewisDepartment of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390-9061, USA.
The University of Texas Southwestern Medical Center · USSouthwestern Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo develop a dual-energy CT method for differentiating and quantifying high-Z contrast elements and to evaluate the limitations based on element concentration and atomic number by using an anthropomorphic phantom study.

methodsMass spectrometry standards for iodine, barium, gadolinium, ytterbium, tantalum, gold, and bismuth were diluted from 10.0 to 0.3 mg/mL, placed inside 7-mL vials, and scanned with dual-energy CT using an abdominal phantom and cylindrical water-filled insert. This procedure was repeated with all seven high-Z elements at six isoattenuating values from 250 to 8 HU. Quantification accuracy was measured using a linear regression model and residual error analysis with 90% limits of agreement. The limit of detection for each element was evaluated using the limit of blank of water. Pairwise differentiation of isoattenuating vials was evaluated using AUC values and the difference in fit angles between the two elements.

resultsEach high-Z element had a unique concentration vector in a two-dimensional plot of Compton scattering versus photoelectric effect attenuations. Mean quantification values were within ± 0.1 mg/mL of the true values for each element with no proportional bias. Limits of detection ranged from 0.35 to 0.56 mg/mL. Pairwise differentiations were proportional to the isoattenuating HU and the angle between the linear fits with mean AUC values increasing from 0.61 to 0.98 at 8 to 250 HU, respectively.

conclusionDual-energy CT can differentiate and quantify isoattenuating high-Z elements. The high-attenuation characteristics and unique concentration vectors of ytterbium, tantalum, gold, and bismuth are well suited for new dual-energy CT contrast agents especially when simultaneously imaged with iodine, barium, or gadolinium. KEY POINTS: • Dual-energy CT can accurately quantify high-Z contrast elements and readily differentiate iodine, barium, and gadolinium from ytterbium, tantalum, gold, and bismuth. • The differentiation and quantification capabilities for high-Z contrast elements are largely unaffected by phantom size and transaxial location within the phantom. • Potential benefits of new CT contrast agents based on these high-Z elements include alternatives for patients with iodine sensitivity, high conspicuity at both 120 and 140 kVp, simultaneous imaging of two contrast agents, and reduced injection volume.

Indexed as

Contrast MediaIodineGadoliniumHumansPhantoms, ImagingTomography, X-Ray ComputedContrast MediaGadoliniumIodineContrast mediaImagingPhantomsTomography, X-ray computed

Identifiers

PMID33856524
OpenAlexW3154607326

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.