Evidence map›Paper›PMID 33856516›Full record

ArticleEuropean radiology2021

Radiation dose reduction with the wide-volume scan mode for interstitial lung diseases.

Alain Abdo, Elige Karam, Théophraste Henry, Sébastien Leygnac, Karim Haioun, Antoine Khalil, Marie-Pierre Debray

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Alain AbdoDepartment of Radiology, Bichat Claude-Bernard Hospital, APHP, 46 rue Henri Huchard, F-75018, Paris, France.
Elige KaramDepartment of Radiology, Bichat Claude-Bernard Hospital, APHP, 46 rue Henri Huchard, F-75018, Paris, France.
Théophraste HenryDepartment of Nuclear Medicine, Institut Gustave Roussy, 114 rue Edouard Vaillant, 94805, Villejuif Cédex, France.
Sébastien LeygnacDepartment of Radiology, Bichat Claude-Bernard Hospital, APHP, 46 rue Henri Huchard, F-75018, Paris, France.
Karim HaiounCT Division, Canon Medical Systems France, 24 quai Gallieni, 92150, Suresnes, France.
Antoine KhalilDepartment of Radiology, Bichat Claude-Bernard Hospital, APHP, 46 rue Henri Huchard, F-75018, Paris, France.
Marie-Pierre DebrayDepartment of Radiology, Bichat Claude-Bernard Hospital, APHP, 46 rue Henri Huchard, F-75018, Paris, France. marie-pierre.debray@aphp.fr.ORCID http://orcid.org/0000-0003-2109-5662
Assistance Publique – Hôpitaux de Paris · FRInserm · FRCanon (France) · FRDélégation Paris 7 · FRInstitut Gustave Roussy · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe wide-volume mode, available on wide-area detector row CTs, has the advantage of reducing exposure time and radiation dose. It is infrequently used for lung diseases. The purpose of this study is to compare image quality and radiation dose of wide-volume chest CT to those of standard helical CT in the setting of interstitial lung diseases.

methodsRetrospective monocentric study including 50 consecutive patients referred for follow-up or screening of interstitial lung diseases, requiring prone scan, acquired with the wide-volume mode, in addition to the routine supine scan, acquired with the helical mode. The optimal collimation in wide-volume mode (320 × 0.5mm or 240 × 0.5mm) was chosen according to the length of the thorax. Wide-volume acquisitions were compared to helical acquisitions for radiation dose (CTDI

resultsMedian CTDI

conclusionsWide-volume mode allows 32% radiation dose reduction compared to the standard helical mode and could be used routinely for diagnosis and follow-up of interstitial lung diseases. KEY POINTS: • Retrospective monocentric study showed that wide-volume scan mode reduces radiation dose by 32% in comparison to helical mode for chest CT in the setting of interstitial lung diseases. • Mild misalignment may be observed at the junction between volumes with the wide-volume mode, without decrease of image quality in the majority of cases and without impairing diagnostic quality. • Wide-volume mode could be used routinely for the diagnosis and follow-up of interstitial lung diseases.

Indexed as

Drug TaperingLung Diseases, InterstitialHumansRadiation DosageRetrospective StudiesTomography, Spiral ComputedImage enhancementLung diseases, interstitialRadiation dosageTomography, spiral computedTomography, X-ray computerized axial

Identifiers

PMID33856516
OpenAlexW3155683433

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.