SynthesisScientific reports2021
A meta-analysis indicating extra-short implants (≤ 6 mm) as an alternative to longer implants (≥ 8 mm) with bone augmentation.
Synthesis in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 14 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 4 syntheses or guidelines pooled it.
- Clinical performance of short implants vs. standard implants in edentulous patients. An umbrella review.Frontiers in oral health · 2025Pooled it
- Short implants compared to regular dental implants after bone augmentation in the atrophic posterior mandible: umbrella review and meta-analysis of success outcomes.International journal of implant dentistry · 2023Pooled it
- Indications for zygomatic implants: a systematic review.International journal of implant dentistry · 2023Pooled it
- Short versus standard implants at sinus augmented sites: a systematic review and meta-analysis.Clinical oral investigations · 2022Pooled it
- Finite Element Analysis of Ultra-Short, Extra-Short, and Conventional Dental Implants in Fibula Free Flap Mandibular Reconstruction.Bioengineering (Basel, Switzerland) · 2026Article
- Bone augmentation effect of implant apex flush with maxillary sinus notch in transcrestal sinus floor elevation: A retrospective study.Clinical oral investigations · 2025Article
- Clinical and radiographic outcomes of extra-short implants (≤ 6 mm) in the posterior atrophic jaws: a retrospective cohort study.International journal of implant dentistry · 2025Article
- Four-mm-short implants in the rehabilitation of posterior atrophic jaws: A retrospective study on 212 patients with a mean follow-up of 8.02 years.Clinical oral implants research · 2024Article
- Survival Rates of Short Dental Implants (≤6 mm) Used as an Alternative to Longer (>6 mm) Implants for the Rehabilitation of Posterior Partial Edentulism: A Systematic Review of RCTs.Dentistry journal · 2024Review
- Extra-short implants (≤ 6.5 mm in length) in atrophic and non-atrophic sites to support screw-retained full-arch restoration: a retrospective clinical study.International journal of implant dentistry · 2023Article
- Fiber-reinforced composite full-arch prosthetic reconstructions supported by three standard, short or extra-short implants: a two-center retrospective study.Clinical oral investigations · 2023Article
- Clinical Evaluation of Short (6 mm) and Longer Implants Placed Side by Side in Posterior Partially Edentulous Area: A 3-Year Observational Study.International journal of dentistry · 2023Article
- Insertion Torque, Removal Torque, and Resonance Frequency Analysis Values of Ultrashort, Short, and Standard Dental Implants: An In Vitro Study on Polyurethane Foam Sheets.Journal of functional biomaterials · 2022Article
- Short versus Longer Implants in Sites without the Need for Bone Augmentation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Materials (Basel, Switzerland) · 2022Review
Corrections and comments
- Commented on by
- Erratum issued
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Extra-short implants, of which clinical outcomes remain controversial, are becoming a potential option rather than long implants with bone augmentation in atrophic partially or totally edentulous jaws. The aim of this study was to compare the clinical outcomes and complications between extra-short implants (≤ 6 mm) and longer implants (≥ 8 mm), with and without bone augmentation procedures. Electronic (via PubMed, Web of Science, EMBASE, Cochrane Library) and manual searches were performed for articles published prior to November 2020. Only randomized controlled trials (RCTs) comparing extra-short implants and longer implants in the same study reporting survival rate with an observation period at least 1 year were selected. Data extraction and methodological quality (AMSTAR-2) was assessed by 2 authors independently. A quantitative meta-analysis was performed to compare the survival rate, marginal bone loss (MBL), biological and prosthesis complication rate. Risk of bias was assessed with the Cochrane risk of bias tool 2 and the quality of evidence was determined with the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. 21 RCTs were included, among which two were prior registered and 14 adhered to the CONSORT statement. No significant difference was found in the survival rate between extra-short and longer implant at 1- and 3-years follow-up (RR: 1.002, CI 0.981 to 1.024, P = 0.856 at 1 year; RR: 0.996, CI 0.968 to 1.025, P = 0.772 at 3 years, moderate quality), while longer implants had significantly higher survival rate than extra-short implants (RR: 0.970, CI 0.944 to 0.997, P < 0.05) at 5 years. Interestingly, no significant difference was observed when bone augmentations were performed at 5 years (RR: 0.977, CI 0.945 to 1.010, P = 0.171 for reconstructed bone; RR: 0.955, CI 0.912 to 0.999, P < 0.05 for native bone). Both the MBL (from implant placement) (WMD: - 0.22, CI - 0.277 to - 0.164, P < 0.01, low quality) and biological complications rate (RR: 0.321, CI 0.243 to 0.422, P < 0.01, moderate quality) preferred extra-short implants. However, there was no significant difference in terms of MBL (from prosthesis restoration) (WMD: 0.016, CI - 0.036 to 0.068, P = 0.555, moderate quality) or prosthesis complications rate (RR: 1.308, CI 0.893 to 1.915, P = 0.168, moderate quality). The placement of extra-short implants could be an acceptable alternative to longer implants in atrophic posterior arch. Further high-quality RCTs with a long follow-up period are required to corroborate the present outcomes.Registration number The review protocol was registered with PROSPERO (CRD42020155342).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.