Evidence map›Paper›PMID 33853657›Full record

ArticleJournal of orthopaedic surgery and research2021

Accuracy of CT for measuring femoral neck anteversion in children with developmental dislocation of the hip verified using 3D printing technology.

Zhencun Cai, Chengzhe Piao, Tianyu Zhang, Lianyong Li, Liangbi Xiang

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Zhencun CaiDepartment of Orthopaedics Surgery, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China.
Chengzhe PiaoDepartment of Orthopaedics Surgery, Central Hospital of Shenyang Medical College, Shenyang, Liaoning Province, China.
Tianyu ZhangDepartment of Orthopaedics Surgery, Central Hospital of Shenyang Medical College, Shenyang, Liaoning Province, China.
Lianyong LiDepartment of Pediatric Orthopaedics, Shengjing Hospital of China Medical University, Shenyang, Liaoning Province, China.
Liangbi XiangDepartment of Orthopaedics Surgery, General Hospital of Northern Theater Command, Shenyang, Liaoning Province, China. xiangliangbi@126.com.
Shenyang Medical College · CNChina Medical University · CNGeneral Hospital of Shenyang Military Region · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate femoral neck anteversion angle (FNA) measurement is of great significance in the diagnosis and treatment of developmental dysplasia of the hip (DDH) in children. The FNA measurement still remains a controversy. We aimed to verify the accuracy of our CT method by 3D printing technology and to evaluate its clinical value.

methodsSixty-eight children with unilateral DDH were enrolled, and their FNA was measured using 2D-CT and 3D-CT, respectively, by three observers. This procedure was repeated 3 months later. The above measurement outcomes were then compared with the results in the 3D-printed femur (3D-PF) model. The FNA in the 3D-PF model was measured by three observers (two radiologists and one orthopedist; all were professors) collectively through electronic angle instrument.

resultsThe primary measurement of FNA at the affected hips by 2D-CT was 44.0 ± 6.1, 49.5 ± 8.9, and 52.8 ± 7.9°, respectively. On the 3D-CT, it was 47.6 ± 5.4, 49.3 ± 6.8, and 48.6 ± 6.2°. Three months later, the FNA on 2D-CT was 49.3 ± 10.5, 42.8 ± 7.4, and 45.1 ± 9.3°, and it was 48.0 ± 6.5, 48.9 ± 7.2, and 49.0 ± 5.7° on 3D-CT, respectively. The FNA in the 3D-PF model at the affected and unaffected hips was 48.5 ± 6.6 and 36.9 ± 13.1°. There were significant differences between 2D-CT and 3D-PF measurements, but no significant difference was found between 3D-CT and 3D-PF measurements. The results by 2D-CT showed significant differences among groups and between the groups. However, the results by 3D-CT had no significant differences among groups or between the groups.

conclusionThe results of our study showed that 3D-CT is a more precise, and reproducible method for FNA measurement in DDH. The FNA at the affected hips is 11.6° larger than the unaffected in DDH children aged 3-8 years.

Indexed as

Printing, Three-DimensionalChildChild, PreschoolDevelopmental Dysplasia of the HipFemaleFemur NeckHumansImaging, Three-DimensionalMaleRetrospective StudiesSensitivity and SpecificityTomography, X-Ray Computed3D printing technologyAnteversion angleCT measurementFemoral neckHip joint

Identifiers

PMID33853657
PMCPMC8045201
OpenAlexW3139097388

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.