ArticleBMC anesthesiology2021
Development and validation of a 3D printed antiviral ventilator filter - a comparative study.
Article in BMC anesthesiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe current coronavirus infectious disease 2019 (COVID-19) pandemic has caused unexpected pressure on medical supplies, interrupting supply chains and increasing prices. The supply of antiviral filters which form an essential part of the ventilator circuit have been affected by these issues. Three-dimensional (3D) printing may provide a solution to some of these issues.
methodsWe designed and tested 3D printed heat and moisture exchange (HME) and antiviral casing. For each casing we tested two different filter materials derived from a sediment water filter cartridge or 1.5-μm glass fiber filter paper. A polyurethane sponge was used for the HME. Each design was tested for circuit leak, circuit compliance, peak inspiratory pressure and casing integrity using methylene blue dye.
resultsWe designed, produced, and tested two different types of antiviral filters with six different internal configurations. Overall, we tested 10 modified filter designs and compared them with the original commercial filter. Except for the combination of 1.5-μm filter paper and 5 mm sponge peak inspiratory pressure and circuit compliance of the filters produced were within the operating limits of the ventilator. All In addition, all filters passed the dye test.
conclusionsOur filter may be of particular importance to those working in low middle-income countries unable to compete with stronger economies. Our design relies on products available outside the healthcare supply chain, much of which can be purchased in grocery stores, hardware stores, or industrial and academic institutions. We hope that these HMEs and viral filters may be beneficial to clinicians who face critical supply chain issues during the COVID-19 pandemic.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials