ArticleCardiovascular engineering and technology2021
Establishing the Biofidelity of a Multiphysics Finite Element Model of the Human Heart.
Article in Cardiovascular engineering and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeAccelerating development of new therapeutic cardiac devices remains a clinical and technical priority. High-performance computing and the emergence of functional and complex in silico models of human anatomy can be an engine to accelerate the commercialization of innovative, safe, and effective devices.
methodsAn existing three-dimensional, nonlinear model of a human heart with flow boundary conditions was evaluated. Its muscular tissues were exercised using electrophysiological boundary conditions, creating a dynamic, electro-mechanical simulation of the kinetics of the human heart. Anatomic metrics were selected to characterize the functional biofidelity of the model based on their significance to the design of cardiac devices. The model output was queried through the cardiac cycle and compared to in vivo literature values.
resultsFor the kinematics of mitral and aortic valves and curvature of coronary vessels, the model's performance was at or above the 95th percentile range of the in vivo data from large patient cohorts. One exception was the kinematics of the tricuspid valve. The model's mechanical use environment would subject devices to generally conservative use conditions.
conclusionsThis conservative simulated use environment for heart-based medical devices, and its judicious application in the evaluation of medical devices is justified, but careful interpretation of the results is encouraged.